Dorsal plating versus volar plating with limited dorsal open reduction in the management of AO type C3 distal radius fractures with impacted articular fragments: A retrospective comparative study

Dorsal plating versus volar plating with limited dorsal open reduction in the management of AO type C3 distal radius fractures with impacted articular fragments: A retrospective comparative study

Objective: The aim of this study was to compare the outcomes of dorsal plating versus volar plating with limited dorsal open reduction in the management of AO type C3 distal radius fractures with impacted articular fragments. Methods: Thirty patients who underwent dorsal plating (Group A) (14 females, 16 males; mean age = 56.8 ± 10.1 years) and 28 who underwent volar plating with limited dorsal open reduction (Group B) (12 females, 16 males; mean age = 55.6 ± 17.7 years) for type C3 distal radius fractures with impacted articular fragments between 2006 and 2019 were retrospectively analyzed. The mean follow-up was 14.5 ± 3.2 months in group A and 13.2 ± 2.4 months in group B. The articular step-off, articular gap and joint penetration by screws on the computed tomography scans were used for radiologic evaluation. The functional outcomes were evaluated with range of motion, grip power, Quick Disabilities of the Arm, Shoulder, and Hand (DASH) score, and Mayo wrist score. Results: No significant difference was found in the step-off distance at 1 year after surgery between the two groups (P < 0.05). The ranges of extension, rotation, and radial and ulnar deviations did not differ between the groups. However, group B had a significantly higher range of flexion in the wrist joint than Group A (P = 0.010). The grip power, DASH score, and Mayo wrist score did not also differ between the groups. Implant removal owing to any discomfort at the operative site was performed in 15 patients (63%) in Group A and 7 patients (28%) in Group B. Conclusion: Similar clinical results can be obtained by both dorsal plating and volar plating with limited dorsal open reduction in treating type C3 distal radius fractures with impacted articular fragments. However, volar plating with limited dorsal open reduction can provide better wrist flexion with a low incidence of complications associated with implantation.

___

  • 1. Rozental TD, Beredjiklian PK, Bozentka DJ. Functional outcome and complications following two types of dorsal plating for unstable fractures of the distal part of the radius. J Bone Jt Surg A. 2003;85(10):1956-1960. 10.2106/00004623- 200310000-00014
  • 2. Zengin EC, Ozcan C, Aslan C, Bulut T, Sener M. Cast immobilization versus volar locking plate fixation of AO type C distal radial fractures in patients aged 60 years and older. Acta Orthop Traumatol Turc. 2019;53(1):15-18. 10.1016/j. aott.2018.10.005
  • 3. Sugun TS, Gurbuz Y, Ozaksar K, Toros T, Kayalar M, Bal E. Results of volar locking plating for unstable distal radius fractures. Acta Orthop Traumatol Turc. 2012;46(1):22-25. 10.3944/AOTT.2012.2623
  • 4. Del Pinal F, Klausmeyer M, Moraleda E, de Piero GH, Ruas JS. Arthroscopic reduction of comminuted intra-articular distal radius fractures with diaphyseal-metaphyseal comminution. J Hand Surg Am. 2014;39(5):835-843. 10.1016/j.jhsa.2014.02.013
  • 5. De Smet A, Lamouille J, Vostrel P, Loret M, Hoffmeyer P, Beaulieu JY. Dorsal approach and internal fixation of impacted intra-articular distal radius fractures with 2.4 mm locking plates. Hand Surg Rehabil. 2016;35(3):203-209. 10. 1016/j.hansur.2016.01.006
  • 6. Rozental TD, Blazar PE. Functional outcome and complications after volar plating for dorsally displaced, unstable fractures of the distal radius. J Hand Surg Am. 2006;31(3):359-365. 10.1016/j.jhsa.2005.10.010
  • 7. Varitimidis SE, Basdekis GK, Dailiana ZH, Hantes ME, Bargiotas K, Malizos K. Treatment of intra-articular fractures of the distal radius: Fluoroscopic or arthroscopic reduction? J Bone Joint Surg Br. 2008;90(6):778-785. 10.1302/ 0301-620X.90B6.19809
  • 8. Chen NC, Jupiter JB. Management of distal radial fractures. J Bone Jt Surg Am. 2007;89(9):2051-2062. 10.2106/00004623-200709000-00025
  • 9. Louis DS. Prospective multi-center trial of a plate for dorsal fixation of distal radius fractures. J Hand Surg. 1998;23(2):353-354. 10.1016/S0363-5023(98) 80140-8
  • 10. Rein S, Schikore H, Schneiders W, Amlang M, Zwipp H. Results of dorsal or volar plate fixation of AO type C3 distal radius fractures: A retrospective study. J Hand Surg. 2007;32(7):954-961. 10.1016/j.jhsa.2007.05.008
  • 11. Meinberg EG, Agel J, Roberts CS, Karam MD, Kellam JF. Fracture and dislocation classification compendium-2018. J Orthop Trauma. 2018;32(Suppl 1):S1- S170. 10.1097/BOT.0000000000001063
  • 12. Abe Y, Tokunaga S, Moriya T. Management of intra-articular distal radius fractures: Volar or dorsal locking plate-which has fewer complications? Hand. 2017;12(6):561-567. 10.1177/1558944716675129
  • 13. Lutsky K, Boyer M, Goldfarb C. Dorsal locked plate fixation of distal radius fractures. J Hand Surg. 2013;38(7):1414-1422. 10.1016/j.jhsa.2013.04.019
  • 14. Kumar S, Khan AN, Sonanis SV. Radiographic and functional evaluation of low profile dorsal versus volar plating for distal radius fractures. J Orthop. 2016;13 (4):376-382. 10.1016/j.jor.2016.06.017
  • 15. Wolfe SW, Hotchkiss RN, Pederson WC, Kozin SH, Cohen MS . Green’s Operative Hand Surgery . Philadelphia: Elsevier ; 2017.
  • 16. Zhou Y, Zhu Y, Zhang X, Tian D, Zhang B. Comparison of radiographic and functional results of die-punch fracture of distal radius between volar locking plating (VLP) and external fixation (EF). J Orthop Surg Res. 2019;14(1):373. 10. 1186/s13018-019-1442-0
  • 17. Ruch DS, Vallee J, Poehling GG, Smith BP, Kuzma GR. Arthroscopic reduction versus fluoroscopic reduction in the management of intra-articular distal radius fractures. Arthroscopy. 2004;20(3):225-230. 10. 1016/j.arthro.2004.01.010
  • 18. Kamath AF, Zurakowski D, Day CS. Low-profile dorsal plating for dorsally angulated distal radius fractures: An outcomes study. J Hand Surg. 2006;31 (7):1061-1067. 10.1016/j.jhsa.2006.05.008
  • 19. Yu YR, Makhni MC, Tabrizi S, Rozental TD, Mundanthanam G, Day CS. Complications of low-profile dorsal versus volar locking plates in the distal radius: A comparative study. J Hand Surg. 2011;36(7):1135-1141. 10.1016/j.jhsa. 2011.04.004
  • 20. Ring D, Jupiter JB, Brennwald J, Buchler U, Hastings H. Prospective multicenter trial of a plate for dorsal fixation of distal radius fractures. J Hand Surg. 1997;22 (5):777-784. 10.1016/S0363-5023(97)80069-X
Acta Orthopaedica et Traumatologica Turcica-Cover
  • ISSN: 1017-995X
  • Başlangıç: 2015
  • Yayıncı: Türk Ortopedi ve Travmatoloji Derneği
Sayıdaki Diğer Makaleler

Comparison of efficacy of Oral versus Intra-articular Corticosteroid Application in the treatment of Frozen Shoulder: An experimental study in rats

Ümit Özgür GÜLER, Vahit Erdal BATTAL, Nebil BAL, Salih BEYAZ, Bekir Murat ÇINAR

The efficacy of angiotensin-converting enzyme inhibitors in preventing postoperative tendon adhesion formation: An experimental study in rats

Tuğçe YASAK, Ayşe ERGAN ŞAHİN, Özay ÖZKAYA, Ergün BOZDAĞ, Özden AKSU SAYMAN

The load transfer effect of monopolar and bipolar radial head prosthesis designs on capitellar cartilage: A comparative biomechanical cadaver study

Abdullah Meriç ÜNAL, Mustafa ÖZKAN, Necmettin TURGUT, Ahmet EKİN, Mehmet AKDEMİR, Mehmet Ozan AŞIK

Dorsal plating versus volar plating with limited dorsal open reduction in the management of AO type C3 distal radius fractures with impacted articular fragments: A retrospective comparative study

Jong Hun BAEK, Jae Hoon LEE, Jung Tae AHN

Analysis of risk factors for re-displacement of pediatric tibia fractures: A retrospective study of 196 cases

Ali TURGUT, Sertan HANCIOĞLU, Mert KUMBARACI

Effect of platelet-rich plasma on bone regenerate consolidation in distraction osteogenesis: An experimental study in rabbits

Bartu SARISÖZEN, Mehmet KARAKAYALI, Yakup ALPAY

Cross-cultural adaptation and validation of the Estonian version of the Oxford Knee Score

Marju RAUKAS, Vahur METSNA, Marika TAMMARU

Preliminary results of iliosacral screws and plate combination in the management of tile B3 pelvic fractures: A retrospective case series

Wei-Bin WANG, Qing-Song FU, Xin-Hua YUAN, Yi ZHENG, Yi-Hong YIN

Clinical outcomes of single-bundle versus double-bundle ACL reconstruction in adolescent elite athletes: A retrospective comparative study

Tunay ERDEN, Göksel DİKMEN, Berkin TOKER, Vahit Emre Özden, Göktuğ FIRATLI, Ömer TAŞER

Tibial slope changes following guided growth by the eight-plate: A retrospective comparative study

Emre ÇULLU, Vahit YILDIZ