A new femoral nail with single distal locking screw for maximum interfragment rotational stability

Objective: One of the problems for interlocking nailing of the femur is interfragment rotation motion, affecting fracture healing. The nails with single distal locking screw are advantageous for decreasing operation time and radiation exposure. We investigated which single distal screw nail is the best for interfragment rotational stability.Methods: We used a total of 30 composite femurs, ten for each group. We determined interfragment rotational displacement of composite femurs with three types of single distal screw nails (10 interlocking nails, 10 compression nails and 10 Mehmet anti-rotation nails compressed by tube) at 6-Nm external- 6 Nm internal and 10 Nm extern- 6 Nm internal torques, which imitating respectively the level walking and descending stairs, using an axial distraction testing machine and a custom designed rotation apparatus.Results: Between 10 Nm external and 6 Nm internal torques with single distal locking screw, the interfragment rotational displacement in the Mehmet nail compressed by the 8 Nm torque wrench was mean 1.14 mm and 540% less than mean 7.31 mm in interlocking nails and 400% less than 5.72 mm in compression nails compressed by the 2.5 Nm torque wrench.Conclusion: The single distal screw Mehmet nail is superior than other single (or even some double) distal screw nails for maximum rotational stability, with no interfragment distraction gap, no superior nail migration, decreased operation time, and less radiation exposure in axially stable transverse and short oblique femur fractures in daily activities like stair descending or level walking.

___

Klein P, Schell H, Streitparth F, Heller M, Kassi JP, Kan- dziora F, et al. The initial phase of fracture healing is spe- cifically sensitive to mechanical conditions. J Orthop Res 2003;21:662-9.

Claes L, Eckert-Hübner K, Augat P. The effect of mechani- cal stability on local vascularization and tissue differentia- tion in callus healing. J Orthop Res 2002;20:1099-105.

Gonschorek O, Hofmann GO, Bühren V. Interlocking compression nailing: a report on 402 applications. Arch Orthop Trauma Surg 1998;117:430-7.

Klein P, Opitz M, Schell H, Taylor WR, Heller MO, Kassi JP, et al. Comparison of unreamed nailing and external fixa- tion of tibial diastases-mechanical conditions during heal- ing and biological outcome. J Orthop Res 2004;22:1072-8.

Citak M, Kendoff D, Gardner MJ, Oszwald M, O'Loughlin PF, Olivier LC, et al. Rotational stability of femoral osteo- synthesis in femoral fractures - navigated measurements. Technol Health Care 2009;17:25-32.

Uzel AP, Deloumeaux J, Rouvillain JL, Laflamme GY, Du- randeau A, Caix P. Comparative study of femoral diaphyse- al morphometry in two male populations, in France and a French West Indies island: an example of clinical relevance of comparative anatomy for orthopedic practice. Surg Ra- diol Anat 2011;33:235-40.

DiBennardo R, Taylor JV. Sex assessment of the femur: a test of a new method. Am J Phys Anthropol 1979;50:635- 7.

Chen AL, Tejwani NC, Joseph TN, Kummer FJ, Koval KJ. The effect of distal screw orientation on the intrinsic stabil- ity of a tibial intramedullary nail. Bull Hosp Jt Dis 2001- 2002;60:80-3.

Aldemir C, Doğan A, İnci F, Sertkaya Ö, Duygun F. Dis- tal locking techniques without fluoroscopy in intramedul- lar nailing. [Article in Turkish] Eklem Hastalik Cerrahisi 2014;25:64-9.

Dursun M, Kalkan T, Aytekin MN, Celik I, Uğurlu M. Does the magnetic-guided intramedullary nailing tech- nique shorten operation time and radiation exposure? Eur J Orthop Surg Traumatol 2014;24:1005-11.

Somerson JS, Rowley D, Kennedy C, Buttacavoli F, Agar- wal A. Electromagnetic navigation reduces surgical time and radiation exposure for proximal interlocking in retro- grade femoral nailing. J Orthop Trauma 2014;28:417-21.

Levin PE, Schoen RW Jr, Browner BD. Radiation expo- sure to the surgeon during closed interlocking intramedul- lary nailing. J Bone Joint Surg Am 1987;69:761-6.

George CJ, Lindsey RW, Noble PC, Alexander JW, Ka- maric E. Optimal location of a single distal interlocking screw in intramedullary nailing of distal third femoral shaft fractures. J Orthop Trauma 1998;12:267-72.

Köse N, Günal I, Wang X, Athanasiou KA, Agrawal CM, Mabrey JD. Setscrew distal locking for intramed- ullary nails: a biomechanical study. J Orthop Trauma 2000;14:414-9.

Wang G, Pan T, Peng X, Wang J. A new intramedullary nailing device for the treatment of femoral shaft fractures: a biomechanical study. Clin Biomech (Bristol, Avon) 2008;23:305-12.

Chao CK, Hsu CC, Wang JL, Lin J. Increasing bending strength of tibial locking screws: mechanical tests and finite element analyses. Clin Biomech (Bristol, Avon) 2007;22:59-66.

Hsu CC, Yongyut A, Chao CK, Lin J. Notch sensitivity of titanium causing contradictory effects on locked nails and screws. Med Eng Phys 2010;32:454-60.

Brown NA, Bryan NA, Stevens PM. Torsional stability of intramedullary compression nails: tibial osteotomy model. Clin Biomech (Bristol, Avon) 2007;22:449-56.

Höntzsch D, Schaser KD, Hofmann GO, Pohlemann T, Hem ES, Rothenbach E, et al. Evaluation of the effective- ness of the angular stable locking system in patients with distal tibial fractures treated with intramedullary nailing: a multicenter randomized controlled trial. J Bone Joint Surg Am 2014;96:1889-97.

Boyer P, Charles P, Loriaut P, Alkhaili J, Mylle G, Pelis- sier A, et al. Results of angular-stable locked intramedul- lary nails in the treatment of distal tibia fractures. Orthop Traumatol Surg Res 2014;100:901-5.

Taylor SJ, Walker PS, Perry JS, Cannon SR, Woledge R. The forces in the distal femur and the knee during walking and other activities measured by telemetry. J Arthroplasty 1998;13:428-37.

Taylor SJ, Walker PS. Forces and moments telemetered from two distal femoral replacements during various activi- ties. J Biomech 2001;34:839-48.

Mückley T, Bühren V. A new titanium nail for the femur. In: Leung KS, Tagland G, Schnettler R, editors. Practice of intramedullary locked nails. Berlin-Heidelberg springer 2006. p. 85-97.

Schneider E, Michel MC, Genge M, Zuber K, Ganz R, Perren SM. Loads acting in an intramedullary nail dur- ing fracture healing in the human femur. J Biomech 2001;34:849-57.

Chong AC, Friis EA, Ballard GP, Czuwala PJ, Cooke FW. Fatigue performance of composite analogue femur constructs under high activity loading. Ann Biomed Eng 2007;35:1196-205.

Griffin LV, Harris RM, Zubak JJ. Fatigue strength of com- mon tibial intramedullary nail distal locking screws. J Or- thop Surg Res 2009;4:11.

Solak S, E Aydın, E Boysan, Kamiloglu S, Adabag C. The results of single distal screw for the treatment of femoral shaft fractures with interlocking intramedullary nailing. Acta Orthop Traumatol Turc 1998;32:37-9.

Hapa O, Muratli HH, Yüksel HY, Celebi L, Doğruyol D, Biçimoğlu A. Single or double distal locking in in- tramedullary nailing of tibial shaft fractures: a prospec- tive randomized study. Ulus Travma Acil Cerrahi Derg 2010;16:33-7.

Kneifel T, Buckley R. A comparison of one versus two dis- tal locking screws in tibial fractures treated with unreamed tibial nails: a prospective randomized clinical trial. Injury 1996;27:271-3.

Uzümcügil O, Doğan A, Yalçinkaya M, Kabukçuoğlu YS. The relationship between anterior knee pain occurring af- ter tibial intramedullary nailing and the localization of the nail in the proximal tibia. [Article in Turkish] Acta Orthop Traumatol Turc 2009;43:386,9.

Demirtaş A, Azboy I, Durakbaşa MO, Uçar BY, Mercan AS, Cakır IA. The relationship between the quadriceps muscle strength and the anterior knee pain occurring after locked intramedullary nailing for tibial diaphysis fractures. [Article in Turkish] Eklem Hastalik Cerrahisi 2011;22:81-4.

Grover J, Wiss DA. A prospective study of fractures of the femoral shaft treated with a static, intramedullary, inter- locking nail comparing one versus two distal screws. Or- thop Clin North Am 1995;26:139-46.
Acta Orthopaedica et Traumatologica Turcica-Cover
  • ISSN: 1017-995X
  • Başlangıç: 2015
  • Yayıncı: Türk Ortopedi ve Travmatoloji Derneği
Sayıdaki Diğer Makaleler

Effectiveness of closed suction drainage tip culture in hip arthroplasty

Jai Hyung PARK, Hyun-Chul SHON, Ji Wan KİM, Se-Jin PARK, Taeg Su KO, Jong-Hyon PARK

Prevalence and characteristics of noise in a series of 282 ceramic-on-ceramic total hip arthroplasties

Mansur HALAI, Bilal JAMAL, Prem Ruben JAYARAM, David MURRAY, Alberto GREGORI, Kumar PERIASAMY

Clinical examination of anterior cruciate ligament rupture: a systematic review and meta-analysis

Wenhan HUANG, Yu ZHANG, Zilong YAO, Linmin MA

Adult spinal deformity: a very heterogeneous population of patients with different needs

Rıfat Emre ACAROĞLU, Özgür DEDE, Ferrán PELLISÉ, Ümit O GÜLER, Montse SÀBAT DOMINGO, Ahmet ALANAY, Francisco Sanchez GRUESO PÉREZ

Effects of positive end-expiratory pressure on arthroscopic shoulder surgery under general anesthesia

Ayşın ERSOY, Mensure ÇAKIRGÖZ, Zekeriya ERVATAN, Özlem KIRAN, Aygen TÜRKMEN, CEM ZEKİ ESENYEL

Chondromyxoid fibroma of the pubic ramus: a case report and literature review

Murat ARIKAN, Güray TOĞRAL, AHMET YILDIRIM, Erdem AKTAŞ

Clavicle fracture after reverse total shoulder arthroplasty: a case report with literature review

Young Sin KIM, Seong-Il WANG, Ju Hong LEE

Effects of cilostazol on fracture healing: an experimental study

Taner ALIÇ, ALPER ÇIRAKLI, Yılmaz ŞAHİN, Yılmaz TOMAK

Dorsal apex curve of the proximal ulna

Arnold ADIKRISHNA, Je Yeon KIM, Aashay L. KEKATPURE, Hyun-Joo LEE, Minjae KIM, In-Ho JEON

Congenital bizarre parosteal osteochondromatous proliferation in unusual location and age: a case report

Sami SÖKÜCÜ, Osman Emre AYCAN, Yavuz ARIKAN, Yavuz Selim KABUKÇUOĞLU