Evaluation of scleral-fixated intraocular lens position anomalies by anterior segment optical coherence tomography

To measure the positions of scleral-fixated intraocular lenses (IOLs) using anterior segment optical coherence tomography (OCT) and to evaluate the influence of the position of scleral-fixated IOL on the quality of vision. Materials and methods: Twenty-six eyes of 26 patients were included in the study. The average age was 57.5 (11 to 78) years. Anterior segment images were taken using slit lamp optical coherence tomography (SL-OCT) and were used to evaluate the position of the IOL. Results: The average amounts of tilt and decentration were 2.25° ± 1.93° and 359.28 ± 194.70 µm, respectively. There was a positive and moderate relationship between tilt and astigmatism caused by the position of the IOL (P = 0.030). No relationship was detected between decentration and the astigmatism caused by the position of the IOL (P = 0.285). Conclusion: Scleral-fixated IOL position can be evaluated with SL-OCT, which is a noncontact, noninvasive, reproducible, and reliable method of evaluation. Anterior segment OCT has been shown to provide sensitive measurements but not in all cases. The present study showed that a tilted scleral-fixated IOL behaved like a toric IOL, and the astigmatism caused by the position of the scleral-fixated IOL therefore could increase or decrease total astigmatism.

Evaluation of scleral-fixated intraocular lens position anomalies by anterior segment optical coherence tomography

To measure the positions of scleral-fixated intraocular lenses (IOLs) using anterior segment optical coherence tomography (OCT) and to evaluate the influence of the position of scleral-fixated IOL on the quality of vision. Materials and methods: Twenty-six eyes of 26 patients were included in the study. The average age was 57.5 (11 to 78) years. Anterior segment images were taken using slit lamp optical coherence tomography (SL-OCT) and were used to evaluate the position of the IOL. Results: The average amounts of tilt and decentration were 2.25° ± 1.93° and 359.28 ± 194.70 µm, respectively. There was a positive and moderate relationship between tilt and astigmatism caused by the position of the IOL (P = 0.030). No relationship was detected between decentration and the astigmatism caused by the position of the IOL (P = 0.285). Conclusion: Scleral-fixated IOL position can be evaluated with SL-OCT, which is a noncontact, noninvasive, reproducible, and reliable method of evaluation. Anterior segment OCT has been shown to provide sensitive measurements but not in all cases. The present study showed that a tilted scleral-fixated IOL behaved like a toric IOL, and the astigmatism caused by the position of the scleral-fixated IOL therefore could increase or decrease total astigmatism.

___

  • Baykara M, Ertürk H, Avcı R, Karataş A, Akova B. Skleral fiksasyon yöntemi ile göz içi lens implantasyonu. Turk J Ophthalmol 2004; 34: 55–60 (article in Turkish with summary in English).
  • Trimarchi F, Stringa M, Vellani G, Iato MS. Scleral fixation of an intraocular lens in the absence of capsular support. J Cataract Refract Surg 1997; 23: 795–797.
  • Bashshur Z, Ma’luf R, Najjar D, Noureddin B. Scleral fixation of posterior chamber intraocular lenses using fascia lata to cover the knots. Ophthalmic Surg Lasers 2002; 33: 445–449.
  • Kozaki J, Tanihara H, Yasuda A, Nagata M. Tilt and decentration of the implanted posterior chamber intraocular lens. J Cataract Refract Surg 1991; 17: 592–595.
  • Boyd BF, Agarwal A. Wavefront analysis and corneal topography. In: Boyd BF, Agarwal A, Alio JL, Krueger RR, Wilson SE, editors. Wavefront Analysis, Aberrometers and Corneal Topography. Panama; Highlights of Ophthalmology; 2003. pp. 217–242.
  • Özdamar A. Aberometreler ve topografi aracılı laser sistemleri. In: The 24th Turkish National Ophthalmology Training, Refractive Surgery; 2004. pp. 65–68.
  • Obstbaum SA, To K. Posterior chamber intraocular lens dislocations and malpositions. Aust N Z J Ophthalmol 1989; 17: 265–271.
  • Lyle WA, Jin JC. An analysis of intraocular lens exchange. Ophthalmic Surg 1992; 23: 453–458.
  • Auffarth GU, Wilcox M, Sims JC, McCabe C, Wesendahl TA, Apple DJ. Analysis of 100 explanted one‐piece and three‐piece silicone intraocular lenses. Ophthalmology 1995; 102: 1144– 1150.
  • Carlson AN, Stewart WC, Tso PC. Intraocular lens complications requiring removal or exchange. Surv Ophthalmol 1998; 42: 417–440.
  • Mamalis N, Davis B, Nilson CD, Hickman MS, Leboyer RM. Complications of foldable intraocular lenses requiring explantation or secondary intervention – 2003 survey update. J Cataract Refract Surg 2004; 30: 2209–2218.
  • Chakrabarti A, Gandhi RK, Chakrabarti M. Ab externo 4-point scleral fixation of posterior chamber intraocular lenses. J Cataract Refract Surg 1999; 25: 420–426.
  • Duffey RJ, Holland EJ, Agapitos PJ, Lindstrom RL. Anatomic study of transsclerally sutured intraocular lens implantation. Am J Ophthalmol 1989; 108: 300–309.
  • Steinert RF, Huang D. Anterior Segment Optical Coherence Tomography. Thorofare, NJ, USA: SLACK Inc.; 2008.
  • Kozaki J, Takahashi F. Theoretical analysis of image defocus with intraocular lens decentration. J Cataract Refract Surg 1995; 21: 552–555.
  • Steiner A, Steinhorst UH, Steiner M, Theischen M, Winter R. [Ultrasound biomicroscopy for localization of artificial lens haptics after transscleral suture fixation]. Ophthalmologe 1997; 94: 41–44.
  • Holland EJ, Djalilian AR, Pederson J. Gonioscopic evaluation of haptic position in transsclerally sutured posterior chamber lenses. Am J Ophthalmol 1997; 123: 411–413.
  • Durak A, Oner HF, Koçak N, Kaynak S. Tilt and decentration after primary and secondary transsclerally sutured posterior chamber intraocular lens implantation. J Cataract Refract Surg 2001; 27: 227–232.
  • Sasaki K, Sakamoto Y, Shibata T, Nakaizumi H, Emori Y. Measurement of postoperative intraocular lens tilting and decentration using Scheimpflug images. J Cataract Refract Surg 1989; 15: 454–457.
  • Teichmann KD, Teichmann IA. The torque and tilt gamble. J Cataract Refract Surg 1997; 23: 413–418.
  • Lubniewski AJ, Holland EJ, Van Meter WS, Gussler D, Parelman J, Smith ME. Histologic study of eyes with transsclerally sutured posterior chamber intraocular lenses. Am J Ophthalmol 1990; 110: 237–243.
  • Hayashi K, Hayashi H, Nakao F, Hayashi F. Intraocular lens tilt and decentration, anterior chamber depth, and refractive error after trans-scleral suture fixation surgery. Ophthalmology 1999; 106: 878–882.
  • Oshika T, Sugita G, Miyata K, Tokunaga T, Samejima T, Okamoto C, Ishii Y. Influence of tilt and decentration of scleral- sutured intraocular lens on ocular higher-order wavefront aberration. Br J Ophthalmol 2007; 91:185–188.
  • Auran JD, Koester CJ, Donn A. In vivo measurement of posterior chamber intraocular lens decentration and tilt. Arch Ophthalmol 1990; 10: 875–879.
  • Hayashi K, Hayashi H, Nakao F, Hayashi F. Intraocular lens tilt and decentration after implantation in eyes with glaucoma. J Cataract Refract Surg 1999; 25: 1515–1520.
  • Hayashi K, Hayashi H, Nakao F, Hayashi F. Anterior capsule contraction and intraocular lens decentration and tilt after hydrogel lens implantation. Br J Ophthalmol 2001; 85: 1294– 1297.
  • Kim JS, Shyn KH. Biometry of 3 types of intraocular lenses using Scheimpflug photography. J Cataract Refract Surg 2001; 27: 533–536.
  • Nejima R, Miyata K, Honbou M, Tokunaga T, Tanabe T, Sato M, Oshika T. A prospective, randomised comparison of single and three piece acrylic foldable intraocular lenses. Br J Ophthalmol 2004; 88: 746–749.
  • Taketani F, Matuura T, Yukawa E, Hara Y. Influence of intraocular lens tilt and decentration on wavefront aberrations. J Cataract Refract Surg 2004; 30: 2158–2162.
  • Baumeister M, Neidhardt B, Strobel J, Kohnen T. Tilt and decentration of three‐piece foldable high‐refractive silicone and hydrophobic acrylic intraocular lenses with 6‐mm optics in an intraindividual comparison. Am J Ophthalmol 2005; 140: 1051–1058.
  • Holladay JT, Piers PA, Koranyi G, van der Mooren M, Norrby NE. A new intraocular lens design to reduce spherical aberration of pseudophakic eyes. J Refract Surg 2002; 18: 683– 691.
  • Tzelikis PF, Akaishi L, Trindade FC, Boteon JE. Spherical aberration and contrast sensitivity in eyes implanted with aspheric and spherical intraocular lenses: a comparative study. Am J Ophthalmol 2008; 145: 827–833.
  • Dietze HH, Cox MJ. Limitations of correcting spherical aberration with aspheric intraocular lenses. J Refract Surg 2005; 21: 541–546.
Turkish Journal of Medical Sciences-Cover
  • ISSN: 1300-0144
  • Yayın Aralığı: Yılda 6 Sayı
  • Yayıncı: TÜBİTAK
Sayıdaki Diğer Makaleler

Is the combined use of insulin resistance indices, including adipokines, more reliable in metabolic syndrome?

Birgül KURAL, Orhan DEĞER, Cihangir EREM, Fulya BALABAN YÜCESAN

The increase of mean platelet volume in patients with Alzheimer disease

Emine Rabia KOÇ, Ertuğrul UZAR, Yasemin ÇIRAK, Yasemin Parlak DEMİR, Atilla İLHAN

Investigation of linezolid resistance in Staphylococcus epidermidis: first reported linezolid resistant coagulase negative staphylococcus in Turkey

Barış YALÇIN, Mehmet Burak SELEK, Bayhan BEKTÖRE, Tuğrul HOŞBUL, Mustafa ÖZYURT

Vitamin C as an antioxidant: evaluation of its role on pulmonary contusion experimental model

Rana SIRMALI, Zeynep GİNİŞ, Mehmet SIRMALI, Okan SOLAK, Bengü ŞELİMAN, Yetkin AĞAÇKIRAN, Namık DELİBAŞ

Association analyses of oxidative stress, aerobic capacity, daily physical activity, and body composition parameters in patients with mild to moderate COPD

Abdurrahman GENÇ, Kağan ÜÇOK, Ümit ŞENER, Tülay KOYUNCU, Olcay AKAR, Sefa ÇELİK, Mehmet ÜNLÜ

The diagnostic efficiency of CT and MRI in ileosigmoid knotting

Sabri Selçuk ATAMANALP, Abdulmecit KANTARCI, Bülent AYDINLI, Gürkan ÖZTÜRK, Şükrü ARSLAN, Ercan KORKUT, Metehan GÜMÜŞ, Abdullah BÖYÜK

Discovering missing heritability and early risk prediction for type 2 diabetes: a new perspective for genome-wide association study analysis with the Nurses' Health Study and the Health Professionals' Follow-Up Study

Hüsamettin GÜL, Yeşim AYDIN SON, Cengizhan AÇIKEL

Effects of oral hormone replacement therapy on mean platelet volume in postmenopausal women

İkbal KAYGUSUZ, Serap Aynur SİMAVLI, Ayla ESER, İlknur İNEGÖL GÜMÜŞ

Effect of nodule size on the reliability of fine-needle aspiration biopsy in thyroid nodules

Ali Erkan UÇAR, Seyit Muhsin SARIKAYA, Ömer PARLAK, Abdussamed YALÇIN

A new knot-supporting instrument and knot technique for laparoscopic surgery

Hasan BÖREKCİ, Elif BÖREKCİ, Hakan AK, Kürşad ZENGİN, Tugay ATALAY, Serhat TANIK