Dissection of mesoappendix in laparoscopic appendectomy: a comparison of monopolar cautery and bipolar vessel sealing system

Various technique and different instruments like endoscopic stapler, endoscopic clip, monopolar cautery, harmonic scalpel, and bipolar vessel sealer can be used in the dissection of appendix mesentery when performing laparoscopic appendectomy. The aim of this study is to evaluate the effects of using monopolar cautery and bipolar vascular sealing instruments in the dissection of mesentery of appendix on the duration of the operation of pediatric patients. Materials and methods: Sixty three patients, operated laparoscopically for acute appendicitis in between June 2008 and June 2009 at the Pediatric Surgery Clinic of Dışkapı Children's Hospital, are evaluated retrospectively. Monopolar cautery was used in 25 patients and bipolar vessel sealer was used in 38 patients. No intraoperative or postoperative complication was seen in any of the patients. None of the patients required conversion to open surgery due to dissection problems of the appendiceal mesentery. Results: The mean duration of operation was 51.08 min in the monopolar cautery group whereas 36, 68 minutes in the bipolar vessel sealing system group. Conclusion: In children, comparing to monopolar cautery, bipolar vessel sealer can be used effectively and safely in the dissection and hemostasis of appendiceal mesentery and is definitely an effective system in decreasing the operation time.

Dissection of mesoappendix in laparoscopic appendectomy: a comparison of monopolar cautery and bipolar vessel sealing system

Various technique and different instruments like endoscopic stapler, endoscopic clip, monopolar cautery, harmonic scalpel, and bipolar vessel sealer can be used in the dissection of appendix mesentery when performing laparoscopic appendectomy. The aim of this study is to evaluate the effects of using monopolar cautery and bipolar vascular sealing instruments in the dissection of mesentery of appendix on the duration of the operation of pediatric patients. Materials and methods: Sixty three patients, operated laparoscopically for acute appendicitis in between June 2008 and June 2009 at the Pediatric Surgery Clinic of Dışkapı Children's Hospital, are evaluated retrospectively. Monopolar cautery was used in 25 patients and bipolar vessel sealer was used in 38 patients. No intraoperative or postoperative complication was seen in any of the patients. None of the patients required conversion to open surgery due to dissection problems of the appendiceal mesentery. Results: The mean duration of operation was 51.08 min in the monopolar cautery group whereas 36, 68 minutes in the bipolar vessel sealing system group. Conclusion: In children, comparing to monopolar cautery, bipolar vessel sealer can be used effectively and safely in the dissection and hemostasis of appendiceal mesentery and is definitely an effective system in decreasing the operation time.

___

  • Takada M, Ichihara T, Kuroda Y: Non-clip laparoscopic colectomy using electrothermal bipolar vessel sealer clinical experiences. Hepatogastroenterology. 2006; 53: 840 -2. 9. Hubner M, Demartines N, Muller S, Dindo D, Clavien PA, Hahnloser D : Prospective randomized study of monopolar scissors, bipolar vessel sealer and ultrasonic shears in laparoscopic colorectal surgery. British J Surgery 2008; 95: 1098–1104.
  • Lantis JC II, Durville FM, Connolly R, Schwaitzberg SD: Comparison of coagulation modalities in surgery. J Laparoendosc Adv Surg Tech A 1998; 8: 381– 94.
  • Ata AH, Bellemore TJ, Meisel JA, Arambulo SM: Distal thermal injury from monopolar electrosurgery. Surg Laparosc Endosc 1993; 3: 323–7.
  • Diamantis T, Kontos M, Arvelakis A, Syroukis S, Koronarchis D, Papalois A et al. Comparison of monopolar electrocoagulation, bipolar electrocoagulation, ultracision, and ligasure. Surg Today 2006; 36: 908–913.
  • Landman J, Kerbl K, Rehman J, Andreoni C, Humphrey PA, Collyer W et al. Evaluation of a vessel sealing system, bipolar electrosurgery, harmonic scalpel, titanium clips, endoscopic gastrointestinal anastomosis vascular staples and sutures for arterial and venous ligation in a porcine model. J Urol 2003; 169: 697-700.
  • Harold KL, Pollinger H, Matthews BD, Kercher KW, Sing RF, Heniford BT: Comparison of ultrasonic energy, bipolar thermal energy, and vascular clips for the hemostasis of small-, medium-, and large-sized arteries Surg Endosc 2003; 17: 1228– 1230.
  • Macario A, Dexter F, Sypal J, Cosgriff N, Heniford BT.: Operative time and other outcomes of the electrothermal bipolar vessel sealing system (LigaSure) versus other methods for surgical hemostasis: a meta-analysis. Surg Innov. 2008; 15: 284-91.
Turkish Journal of Medical Sciences-Cover
  • ISSN: 1300-0144
  • Yayın Aralığı: Yılda 6 Sayı
  • Yayıncı: TÜBİTAK
Sayıdaki Diğer Makaleler

Feminizing genitoplasty: an evaluation of 41 patients in 8 years

Emrah ŞENEL, Ervin MAMBET, Tuğrul TİRYAKİ, Ziya LİVANELİOĞLU, Fatih AKBIYIK, Halil ATAYURT

Effects of vitamin A and C and melatonin on 3-nitrotyrosine formation in guinea pig heart under lipopolysaccharide-induced stress

Nurten TÜRKÖZKAN, Behzat ÇİMEN, Mehmet Kemal ERBİL, Emin Özgür AKGÜL, Halil YAMAN, Hakan YAREN, Tuncer ÇAYCI, Ömer ÖZCAN, Melik SEYREK, Gülcan Yasemin KURT, İbrahim AYDIN, Erdinç ÇAKIR

Serum prolidase activity in patients with degenerative and rheumatic heart valve diseases

Recep DEMİRBAĞ, Abdullah TAŞKIN, Kaan KIRALİ, Murat Bülent RABUŞ, Nurten AKSOY, Yusuf SEZEN, Mehmet TAŞAR, Cevat YAKUT

Chronic pain and depression: A descriptive survey among adult primary health care centre patients

Paksoy Nüket ERBAYDAR, Nesrin ÇİLİNGİROĞLU

Gastric volvulus due to diaphragmatic eventration and paraesophageal hernia

Nurettin Özgür DOĞAN, Fikret BİLDİK, Ahmet DEMİRCAN, Ayfer KELEŞ, Gökhan AKSEL

Prediction of prostate cancer using decision tree algorithm

Kemal Hakan GÜLKESEN, Sebahat ÖZDEM, Osman SAKA, İsmail Türker KÖKSAL

Penile Mondor's disease can be effectively treated with the use of an acetyl salicylic acid and pentoxifylline combination

Mürsel DAVARCI, Eşref Oğuz GÜVEN, Ahmet GÖKÇE, Fatih Rüştü YALÇINKAYA, Ahmet Namık KİPER, Mevlana Derya BALBAY

Does central corneal thickness correlate with haemoglobin A1c level and disease severity in diabetes type II?

Mehmet Özgür ZENGİN, Zeynep ÖZBEK, Gül ARIKAN, İsmet DURAK, Ali Osman SAATCİ

Restricted universal guidelines for ROP screening: A possible misguidance for middle income countries

Huban ATİLLA, Tomris TÜRMEN, Sadet ARSAN, Figen BATUOĞLU, Begüm ATASAY, Ömer ERDEVE

Two siblings with Netherton syndrome

Selma EMRE, Ahmet METİN, Aykut ONURSEVER, D. Deniz DEMİRSEREN, Burçin KAFTAN, Ahu YORULMAZ