Comparison of two different right-sided double-lumen tubes with diff erent designs
Comparison of two different right-sided double-lumen tubes with diff erent designs
Aim: To compare usage of 2 right-sided double-lumen tubes (RDLTs) with diff erent designs in thoracic anesthesia. Although the left -sided double-lumen tube (DLT) is preferred, the RDLT is necessary in some circumstances. Materials and methods: A total of 40 patients undergoing left thoracotomy were divided into 2 groups receiving a Rüsch or Sheridan RDLT. The position of the RDLT was verifi ed by clinical evaluation. It was also checked by fiberoptic bronchoscope (FOB). When malposition was detected, it was corrected using the FOB. The correct installation time of the RDLT, frequency of bronchoscopy, and left lung collapse time were recorded. Results: According to the bronchoscopic assessment, the rates of patients with a misplaced RDLT in the supine (40% vs. 50%) and lateral decubitis position (35% vs. 30%) were similar between the groups (P > 0.05). Ratios of total malpositions to total bronchoscopies were similar. The most frequent malposition types were displacement of RDLTs proximally or distally. Correct RDLT installation time (262 vs. 291 s) and collapse time of the left lung (215 vs. 234 s) were comparable between the groups (P > 0.05). Conclusion: With the aid of bronchoscopic evaluation, our data suggest that Rüsch and Sheridan RDLTs are not superior to each other in one-lung ventilation. They were similar in terms of malpositions.
___
- 1. Gothard JWW. Anaesthetic equipment for thoracic surgery. Anaesthesia and Intensive Care Medicine 2005; 6: 425-7.
- 2. Benumof JL. Separation of the two lungs (double-lumen tube and bronchial blocker intubation). In: Benumof JL, editor. Anesthesia for thoracic surgery. Philadelphia: WB Saunders; 1995. p. 330-89.
- 3. Benumof JL, Alfery DD. Anesthesia for Thoracic Surgery. In: Miller RD, editor. Anesthesia. 5th ed. Philadelphia: Churchill- Livingstone; 2000. p. 1665-752.
- 4. Campos JH, Massa FC. Is there a better right-sided tube for one-lung ventilation? A comparison of the right-sided doublelumen tube with the single-lumen tube with right-sided enclosed bronchial blocker. Anesth Analg 1998; 86: 696-700.
- 5. Benumof JL, Partridge BL, Salvatierra C, Keating J. Margin of safety in positioning modern double-lumen endotracheal tubes. Anesthesiology 1987; 67: 729-38.
- 6. Campos JH, Massa FC, Kernstine KH. The incidence of right upper-lobe collapse when comparing a right-sided doublelumen tube versus a modifi ed left double-lumen tube for left - sided thoracic surgery. Anesth Analg 2000; 90: 535-40.
- 7. Cohen E. Double-lumen tube position should be confi rmed by fiberoptic bronchoscopy. Curr Opin Anaesthesiol 2004; 17: 1-6.
- 8. Cohen E. Methods of lung separation. Curr Opin Anaesthesiol 2002; 15: 69-78.
- 9. Campos JH. Current techniques for perioperative lung isolation in adults. Anesthesiology 2002; 97: 1295-301.
- 10. McKenna MJ, Wilson RS, Botelho RJ. Right upper lobe obstruction with right-sided double-lumen endobronchial tubes: a comparison of two tube types. J Cardiothorac Anesth 1988; 2: 734-40.
- 11. Alliaume B, Coddens J, Deloof T. Reliability of auscultation in positioning of double-lumen endobronchial tubes. Can J Anaesth 1992; 39: 687-90.
- 12. Klein U, Karzai W, Bloos F, Wohlfarth M, Gottschall R, Fritz H et al. Role of fi beroptic bronchoscopy in conjunction with the use of double-lumen tubes for thoracic anesthesia. Anesthesiology 1998; 88: 346-50.
- 13. Ehrenfeld JM, Walsh JL, Sandberg WS. Right and left -sided Mallinckrodt double-lumen tubes have identical clinical performance. Anesth Analg 2008; 106: 1847-52.
- 14. Van Dyck MJ, Astiz I. Kinking of a right-sided double-lumen tube in the right upper lobe bronchus. Anesthesiology 1994; 80: 1410-1.
- 15. Hurford WE, Alfi lle PH. A quality improvement study of the placement and complications of double-lumen endobronchial tubes. J Cardiothorac Vasc Anesth 1993; 7: 517-20.
- 16. Saito S, Dohi S, Naito H. Alteration of double-lumen endobronchial tube position by flexion and extension of the neck. Anesthesiology 1985; 62: 697-8.
- 17. Inoue S, Nishimine N, Kitaguchi K, Furuya H, Taniguchi S. Double lumen tube location predicts tube malposition and hypoxaemia during one lung ventilation. Br J Anaesth 2004; 92: 195-201.
- 18. Ramsay MAE. Right-sided double-lumen endobronchial tubes for left -sided thoracic surgery. Anesth Analg 2000; 91: 762.
- 19. Campos JH, Hallam EA, Natta TV, Kernstine KH. Devices for lung isolation used by anesthesiologists with limited thoracic experience. Anesthesiology 2006; 104: 261-6.
- 20. Bussières JS, Slinger P. Correct positioning of double-lumen tubes. Can J Anesth 2012; 59: 431-6.
- 21. Cohen E. Methods of lung separation. Minerva Anestesiol 2004; 70: 313-8.
- 22. Hoşten T, Topçu S. The importance of bronchoscopic anatomy for anesthesiologists. Tuberk Toraks 2011; 59: 416-26.