A novel hand-held device for the measurement of ocular alignment

The measurement of ocular alignment can be challenging and difficult to reproduce. A method for the measurement of ocular alignment with accuracy, speed, and reproducibility would be a useful clinical addition. Materials and methods: A hand-held device consisting of a rotary prism and a red Maddox rod was constructed. This was used to evaluate 18 patients with ocular misalignment and the results were compared with the ones obtained using the prism cover testing. Results: The results from the hand-held device showed a close correlation with those of the prism cover test. Conclusion: The hand-held instrument is a useful method to quantify ocular misalignment and correlates with the prism cover test results.

A novel hand-held device for the measurement of ocular alignment

The measurement of ocular alignment can be challenging and difficult to reproduce. A method for the measurement of ocular alignment with accuracy, speed, and reproducibility would be a useful clinical addition. Materials and methods: A hand-held device consisting of a rotary prism and a red Maddox rod was constructed. This was used to evaluate 18 patients with ocular misalignment and the results were compared with the ones obtained using the prism cover testing. Results: The results from the hand-held device showed a close correlation with those of the prism cover test. Conclusion: The hand-held instrument is a useful method to quantify ocular misalignment and correlates with the prism cover test results.
Turkish Journal of Medical Sciences-Cover
  • ISSN: 1300-0144
  • Yayın Aralığı: Yılda 6 Sayı
  • Yayıncı: TÜBİTAK
Sayıdaki Diğer Makaleler

Comparison of quality of life in hepatitis B virus carriers versus chronic hepatitis B virus carriers versus the normal population

Tansu YAMAZHAN, Işıkgöz Meltem TAŞBAKAN, Özkören Şebnem ÇALIK, Önen Özen SERTÖZ, Hüsnü PULLUKÇU, Oğuz Reşat SİPAHİ

The comparison of MRI findings with severity score of incontinence after pubovaginal sling surgery

Gökhan TEMELTAŞ, Bilali GÜMÜŞ, Yılmaz Gülgün OVALI, Serdar TARHAN, Cihan GÖKTAN, Selim SERTER

Samsun’da yaşlılar arasında ev kazaları sıklığı ve etkileyen faktörler

Özal Nimet ORUÇ, Sevgi CANBAZ, Yıldız PEKŞEN, Hülya DOĞAN, Ferhan CANTÜRK, Berna TANDER

Caustic esophageal injury decreases the number of interstitial cells of Cajal in the rat esophagus

Tutku SOYER, Turan KANMAZ, Murat ÇAKMAK, Pınar ATASOY, Salih SOMUNCU, Şebnem AYVA

Histopathological effects of chronic fluorosis on the liver of mice (Swiss albino)

Evren KOÇ, Başaran KARADEMİR, Yusuf ERSAN, İsmail ARI

N-acetyltransferase 2 gene polymorphisms and susceptibility to prostate cancer: a pilot study in the Turkish population

Cumhur GÜNDÜZ, Rukiye ÖZEL, Nejat TOPÇUOĞLU, Bozok Vidan ÇETİNTAŞ, .Çağdaş AKTAN, Buket KOSOVA, Aslı TETİK, Fatma Zuhal EROĞLU, Ahmet Çağ ÇAL, İbrahim Kadri CÜREKLİBATIR

Serum total sialic acid, lipid peroxidation, and glutathione reductase levels in patients with rheumatoid arthritis

Surapaneni Krishna MOHAN, Vishnu PRIYAV

Effect of essential hypertension on QTc dispersion in patients with intracerebral haemorrhage

Özcan YILMAZ, Ahmet BAYDIN, Dursun AYGÜN, Bülent ŞİŞMAN, Mehmet Selim NURAL

A novel hand-held device for the measurement of ocular alignment

Uğur E. ALTIPARMAK, Esra KARABULUT, Earic R. ERGENBERGER

Deneysel alerjik konjonktivit modelinde kafeik asit feniletil ester (CAPE), olopatadine hidroklorid ve deksametazon sodyum fosfat’ın etkinliklerinin karşılaştırılması

Erdinç AYDIN, Helin Deniz DEMİR, Hüseyin ÖZYURT, Ünal ERKORKMAZ