Modeling and analysis of a novel dual open-end stator windings wound rotor synchronous machine with dampers

Modeling and analysis of a novel dual open-end stator windings wound rotor synchronous machine with dampers

This work presents a novel wound rotor synchronous machine with dampers with dual three-phase open-end stator windings. The aim of the proposed machine is to improve the power segmentation and the availability of the drive system. The mathematical model of this machine is presented in the Park reference frame. This machine is supplied by four 2-level inverters, where each inverter is dimensioned for quarter power of the machine. For comparison purposes, we use a double star synchronous machine fed by two 2-level inverters. Comparative simulation analysis using THD voltage, THD stator current, and torque undulation showed signi cant advantages of the proposed machine.

___

  • [1] Stemmler H. High-power industrial drives. Proc IEEE 1994; 82: 1266-1286.
  • [2] Franquelo LG, Rodriguez J, Leon JI, Kouro S, Portillo R, Prats MAM. The age of multilevel converters arrives. IEEE Ind Electron M 2008; 2: 28-39.
  • [3] Kouro S, Malinowski M, Gopakumar K, Pou J, Franquelo LG, Wu B, Rodriguez J, Perez MA, Leon JI. Recent advances and industrial applications of multilevel converters. IEEE T Ind Electron 2010; 57: 2553-2580.
  • [4] Nabae A, Takahashi I, Akagi H. A new neutral-point-clamped PWM inverter. IEEE T Ind Appl 1981; IA-17.
  • [5] Meynard TA, Foch H. Multi-level conversion: high voltage choppers and voltage-source inverters. In IEEE 1992 Power Electronics Specialists Conferences, 29 June{3 July 1992; Toledo, OH, USA: IEEE. pp. 397-403.
  • [6] Lai JS, Peng FZ. Multilevel converters a new breed of power converters. IEEE T Ind Appl 1996; 32: 509-517.
  • [7] Singh GK, Pant V, Singh YP. Voltage source inverter driven multi-phase induction machine. Elsevier Journal of Computer and Electrical Engineering 2003; 29: 813-834.
  • [8] Singh GK, Nam K, Lim SK. A simple indirect eld-oriented control scheme for multiphase induction machine. IEEE T Ind Electron 2005; 52: 1177-1184.
  • [9] Jones M, Vukosavic SN, Dujic D, Levi E. A synchronous current control scheme for multiphase induction motor drives. IEEE T Energy Conver 2009; 24: 860-868.
  • [10] Abdel-Khalik AS, Morsy AS, Ahmed S, Massoud AM. Effect of stator winding connection on performance of ve- phase induction machines. IEEE T Ind Electron 2014; 61: 3-19.
  • [11] Rojoi R, Farina F, Griva G, profumo R, Tenconi A. Direct torque control for dual three-phase induction motors drives. IEEE T Ind Appl 2005; 41: 1627-1636.
  • [12] Marouani K, Baghli L, Hadiouche D, Kheloui A, Rezzoug A. A new PWM strategy based on a 24-sector vector space decomposition for a six-phase VSI-fed dual stator induction motor. IEEE T Ind Electron 2008; 55: 1910-1920.
  • [13] Samuli K, Jussi K, Pasi P, Pertti S, Olli P. Determination of the inductance parameters for the decoupled d-q model of double-star permanent-magnet synchronous machines. IET Electr Power App 2014; 8: 39-49.
  • [14] Guizani S, Ben Ammar F. The eigenvalues analysis of the double star induction machine supplied by redundant voltage source inverter. International Review of Electrical Engineering 2008; 3: 300-311.
  • [15] Ben Ammar F, Guizani S. The improvement availability of a double star asynchronous machine supplied by redundant voltage source inverter. Journal of Electrical System 2008; 4.
  • [16] Stemmler H, Geggenbach P. Con gurations of high power voltage source inverter drives. Proc EPE Conference 1993; Brighton, UK; 5: 7-12.
  • [17] Somasekhar VT, Baiju MR, Gopakumar K. Dual two-level inverter scheme for an open-end winding induction motor drive with a single DC power supply and improved DC bus utilization. IEE Proceeding Electric Power Applications 2004; 151: 230-238.
  • [18] Srinivas S, Somasekhar VT. Space-vector-based PWM switching strategies for a three-level dual-inverter-fed open- end winding induction motor drive and their comparative evaluation. IET Electr Power App 2008; 2: 19-31.
  • [19] Figarado S, Sivakumar K, Ramchand R, Das A, Patel C, Gopakumar K. Five-level inverter scheme for an open-end winding induction machine with less number of switches. IET Power Electron 2010; 3: 637-647.
  • [20] Sandulescu AP, Meinguet F, Kestelyn X, Semail E, Bruyere A. Flux-weakening operation of open-end winding drive integrating a cost-effective high-power charger. IET Electrical Systems in Transportation 2013; 3: 10-21.
  • [21] Bodo N, Levi E, Jones M. Investigation of carrier-based PWM techniques for a ve-phase open-end winding drive topology. IEEE T Ind Electron 2013; 60: 2054-2065.
  • [22] Guizani S, Ben Ammar F. The dual open-end winding induction machine fed by quad inverters in degraded mode. International Journal of Scienti c & Engineering Research 2013; 4.
  • [23] Guizani S, Ben Ammar F. Dual open-end stator winding induction machine fed by redundant voltage source inverters. Turk J Elec Eng & Comp Sci 2015; 23: 2171-2181.