Analysis of active power control algorithms of variable speed wind generators for power system frequency stabilization

Analysis of active power control algorithms of variable speed wind generators for power system frequency stabilization

A modified control algorithm of a variable speed wind generator (VSWG) for supporting power system frequency stabilization is presented in this paper. A comparison of the performance of this algorithm with active power control algorithms of VSWGs for supporting power system frequency stabilization, as published in the scientific literature, is also presented. A systematic method of analysis of the modified control algorithm is described in detail. It has been shown that by using the modified control algorithm, the VSWG truly emulates the inertial response of a conventional steam-generating unit with synchronous generators during the initial/inertial phase of primary frequency control, following loss of active power generation when wind speed is between cut-in (i.e. 4 m/s) and rated speed (i.e. 12 m/s). By the inclusion of a signal proportional to the frequency deviation as a power reference to the torque controller feedback loop of the modified control algorithm, it is ensured that the contribution of the VSWG to frequency stabilization is independent of the initial wind speed. This independence is kept as long as the wind speed is above the cut-in wind speed and slightly below the rated wind speed (i.e. 12 m/s). One of the important features of the modified control algorithm, namely a near-proportional relationship between the initial wind turbine speed and the maximum wind turbine speed variation during the inertial response, has been identified. The results of the analysis provide a solid basis for further research in the area of VSWG contribution to frequency stabilization.

___

  • [1] Anaya-Lara O, Jenkins N, Ekanayake J, Cartwright P, Hughes M. Wind Energy Generation: Modelling and Control. 1st ed. Chichester, UK: Wiley, 2009.
  • [2] Yingcheng X, Nengling T. Review of contribution to frequency control through variable speed wind turbine. Renew Energ 2011; 36: 1671–1677.
  • [3] Ackerman T. Wind Power in Power Systems. 2nd ed. Chichester, UK: Wiley, 2012.
  • [4] Aho J, Buckspan A, Laks J, Fleming P, Dunne F, Churchfield M, Jeong Y, Pao L, Johnson K. Tutorial of wind turbine control for supporting grid frequency through active power control. In: American Control Conference 2012; 27–29 June 2012; Montreal, Canada. New York, NY, USA: IEEE. pp. 3120–3131.
  • [5] Hughes FM, Anaya-Lara O, Jenkins N, Strbac G. Control of DFIG-based wind generation for power network support. IEEE T Power Syst 2005; 20: 1958–1966.
  • [6] Morren J, de Haan SWH, Kling WL, Ferreira JA. Wind turbines emulating inertia and supporting primary frequency control. IEEE T Power Syst 2006; 21: 433–434.
  • [7] Ramtharan G, Ekanayake JB, Jenkins N. Frequency support from doubly fed induction generator wind turbines. IET Renew Power Gen 2007; 1: 3–9.
  • [8] Ullah NR, Thiringer T, Karlsson D. Temporary primary frequency control support by variable speed wind turbines— potential and applications. IEEE T Power Syst 2008; 23: 601–612.
  • [9] Conroy JF, Watson R. Frequency response capability of full converter wind turbine generators in comparison to conventional generation. IEEE T Power Syst 2008; 23: 649–656.
  • [10] Keung PK, Li L, Banakar H, Ooi BT. Kinetic energy of wind-turbine generators for system frequency support. IEEE T Power Syst 2009; 24: 279–287.
  • [11] Duval J, Meyer B. Frequency behavior of grid with high penetration rate of wind generation. In: IEEE 2009 PowerTech 2009 Conference; 28 June–2 July 2009; Bucharest, Romania. New York, NY, USA: IEEE. pp. 1–6.
  • [12] Akbari M, Madani SM. Participation of DFIG based wind turbines in improving short term frequency regulation. In: ICEE 2010 Electrical Engineering Conference; 11–13 May 2010; Isfahan, Iran. New York, NY, USA: IEEE. pp. 874–879.
  • [13] Mauricio JM, Marano A, Gomez-Exposito A, Ramos JLM. Frequency regulation contribution through variablespeed wind energy conversion systems. IEEE T Power Syst 2009; 24: 173–180.
  • [14] Gautam D, Goel L, Ayyanar R, Vittal V, Harbour T. Control strategy to mitigate the impact of reduced inertia due to doubly fed induction generators on large power systems. IEEE T Power Syst 2011; 26: 214–224.
  • [15] Sun YZ, Zhang ZS, Li GJ, Lin J. Review on frequency control of power systems with wind power penetration. In: POWERCON 2010 International Conference on Power Systems Technology; 24–28 October 2010; Hanghzou, China. New York, NY, USA: IEEE. pp. 1–8.
  • [16] Miller NW, Price WW, Sanchez-Gasca JJ. Dynamic Modeling of GE 1.5 and 3.6 Wind Turbine-Generators. Schenectady, NY, USA: GE-Power System Energy Consulting, 2003.
  • [17] Miller NW, Sanchez-Gasca JJ, Price WW, Delmerico RW. Dynamic modeling of GE 1.5 and 3.6 MW wind turbinegenerators for stability simulations. In: IEEE 2003 Power Engineering Society General Meeting; 13–17 July 2003; Toronto, Canada. New York, NY, USA: IEEE. pp. 1977–1983.
  • [18] Ellis A, Kazachkov Y, Muljadi E, Pourbeik P, Sanchez-Gasca J. Description and technical specifications for generic WTG models—a status report. In: IEEE 2011 Power Systems Conference and Exposition; 20–23 March 2011; Phoenix, AZ, USA. New York, NY, USA: IEEE. pp. 1–8.
  • [19] Clark K, Miller NW, Sanchez-Gasca JJ. Modeling of GE Wind Turbine-Generators for Grid Studies. Schenectady, NY, USA: General Electric International, 2010.
  • [20] Ullah NR. Wind power: added value for network operations. PhD, Chalmers University of Technology, Goteborg, Sweden, 2008.
  • [21] Anderson PM, Fouad AA. Power System Control and Stability. 2nd ed. New York, NY, USA: Wiley, 2003.
Turkish Journal of Electrical Engineering and Computer Sciences-Cover
  • ISSN: 1300-0632
  • Yayın Aralığı: Yılda 6 Sayı
  • Yayıncı: TÜBİTAK