The Investigation of The Anisotropic Analytical Algorithm (AAA) and the Acuros XB (AXB) Dose Calculation Algorithms Accuracy in Surface and Buildup Region for 6 MV Photon Beam Using Gafchromic EBT3 Film

The Investigation of The Anisotropic Analytical Algorithm (AAA) and the Acuros XB (AXB) Dose Calculation Algorithms Accuracy in Surface and Buildup Region for 6 MV Photon Beam Using Gafchromic EBT3 Film

OBJECTIVE Due to the complexity of build-up region dosimetry, treatment planning system (TPS) calculations may present significant inaccuracy in surface and buildup regions. The main aim of the current study was to investigate the calculated build-up and surface doses for 6 MV photon beams by Eclipse TPS version 15.1 Anisotropic Analytical Algorithm (AAA) and Acuros XB (AXB) algorithm. METHODS Calculations were compared to surface doses measured by Markus parallel-plate ionization chamber which is admitted asan alternative to the extrapolation chambers to obtain the most accurate results for surface region and by Gafchromic EBT3 film which is frequently preferred in in vivo dosimetry (IVD) applications for skin dose measurements because of their practical usage. The measurements were made for 5×5, 10×10, and 20×20 cm2 field sizes at the surface and in the buildup region of 6 MV. Dosimetry systems were placed in a water equivalent solid phantom; all measurements were performed at 100 cm source-detector distance. RESULTS The surface doses using 6 MV photon beams for 5×5, 10×10, and 20×20 cm2 field sizes at 0.07 mm was found to be 14.00% and 12.79%; 19.69% and 18.80%; and 30.87% and 27.07% for Markus chamber and Gafchromic EBT3 film, respectively. CONCLUSION In clinics, to be sure of the correctness of surface and buildup region dose calculation, QA procedures must be performed for all algorithms implanted in TPS before using them for patient treatment planning. Since it exhibits the similar results by Markus parallel plate ion chamber in the surface and buildup region, Gafchromic EBT3 film can be a preferable dosimeter in IVD.

___

  • 1. de Vera P, Abril I, Garcia-Molina R. Water equivalent properties of materials commonly used in proton dosimetry. Appl Radiat Isot 2014;83(Pt B):122–7.
  • 2. Zhuang AH, Olch AJ. Validation of OSLD and a treatment planning system for surface dose determination in IMRT treatments. Med Phys 2014;41(8):081720.
  • 3. Higgins PD, Han EY, Yuan JL, Hui S, Lee CK. Evaluation of surface and superficial dose for head and neck treatments using conventional or intensity-modulated techniques. Phys Med Bio 2007;52(4):1135–46.
  • 4. Qi ZY, Deng XW, Huang SM, Zhang L, He ZC, Li XA, et al. In vivo verification of superficial dose for head and neck treatments using intensity-modulated techniques. Med Phys 2009;36(1):59–70.
  • 5. Panettieri V, Barsoum P, Westermark M, Brualla L, Lax I. AAA and PBC calculation accuracy in the surface build-up region in tangential beam treatments. Phantom and breast case study with the Monte Carlo code PENELOPE. Radiother Oncol 2009;93(1):94–101.
  • 6. Gerbi BJ, Khan FM. Measurement of dose in the buildup region using fixed-separation plane-parallel ionization chambers. Med Phys 1990;17(1):17–26.
  • 7. Tatsiana AR, Patrick H. Surface dose measurements with commonly used detectors: A consistent thickness correction. J Appl Clin Med Phys 2015;16(5):358–66.
  • 8. Devic S, Seuntjens J, Abdel-Rahman W, Evans M, Olivares, M, Podgorsak EB, et al. Accurate skin dose measurement using radiochromic film in clinical applications. Med Phys 2006;33(4):1116–24.
  • 9. Cao Y, Yang X, Yang Z, Qiu X, Lv Z, Lei M, et al. Superficial dose evaluation of four dose calculation algorithms. Radiat Phys Chem 2017;137(1):23–8.
  • 10. Scarantino CH, Prestidge BR, Anscher MS, Ferree CR, Kearns WT, et al. The observed variance between predicted and measured radiation dose in breast and prostate patients utilizing an in vivo dosimeter. Int J Radiat Oncol Biol Phys 2008;72(2):597–604.
  • 11. Velkley DE, Manson DJ, Purdy JA, Oliver GD Jr. Build up region of megavoltage photon radiation sources. Med Phys 1975;2(1):14–9.
  • 12. Van Battum LJ, Hoffmans D, Piersma H, Heukelom S. Accurate dosimetry with GafChromic EBT film of a 6 MV photon beam in water: What level is achievable? Med Phys 2008;35(2):704–16.
  • 13. Bilge H, Çakır A, Okutan M, Acar H. Surface dose measurements with GafChromic EBT film for 6 and 18MV photon beams. Phys Med 2009;25(2):101–4.
  • 14. Gwi AC, Ralston A, Mo TM, Martin D, Pickard S, Kim JH, et al. In vivo and phantom measurements versus Eclipse TPS prediction of near surface dose for SBRT treatments. J Phys 2014;489:012008.
  • 15. Bush K, Gagne IM, Zavgorodni S, Ansbacher W, Beckham W. Dosimetric validation of Acuros XB with Monte Carlo methods for photon dose calculations. Med Phys 2011;38(4):2208–21.
  • 16. Lloyd S, Ansbacher W. Evaluation of an analytic linear Boltzmann transport equation solver for high-density inhomogeneities. Med Phys 2013;40(1):011707.
  • 17. Alhakeem EA, Al Shaikh S, Rosenfeld AB, Zavgorodni SF. Comparative evaluation of modern dosimetry techniques near low and high-density heterogeneities. J Appl Clin Med Phys 2015;16(5):142–58.
Türk Onkoloji Dergisi-Cover
  • ISSN: 1300-7467
  • Başlangıç: 2015
  • Yayıncı: Ali Cangül
Sayıdaki Diğer Makaleler

Second Primary Malignancies in Pediatric and Adolescent Nasopharyngeal Carcinoma Survivors: Experience of a Single-center

Kübra ÖZKAYA, Musa ALTUN, Rejin KEBUDİ, Sema BÜYÜKKAPU BAY

Mood Status in Patients with Gastrointestinal Tract Cancer Undergoing Radiotherapy: A Randomized Cross-sectional Study

Moloud RADFAR, Hamid Reza KHALKHALİ, Haleh GHAVAMİ, Tohid TAYEFEH, Mohsen MANSOORİ

Role of Radiotherapy in Kaposi’s Sarcoma: Review of the Literature

Süheyla AYTAÇ ARSLAN, İpek Pınar ARAL, Yılmaz TEZCAN, Alaettin ARSLAN, Neşe GÖÇER GÜROK, Gonca ALTINIŞIK İNAN, Selcan TEKİN

The Importance of Apoptosis in Cancer Development and Treatment

Elmas KASAP, İrem Nur GÖKBAYRAK ATAY, Ayhan Hilal GEZER

The Relationship between the Care Burden, Anxiety, and Social Support Levels of Mothers of Children with Cancer

Remziye SEMERCİ, Melahat AKGÜN KOSTAK, İsmail ÇETİNTAŞ, Esra Nur KOCAASLAN

Chemoradiotherapy in the Management of Cardiac Metastases: A Case Report and Brief Review

Süheyla AYTAÇ ARSLAN, İpek Pınar ARAL, Yılmaz TEZCAN, Karabekir ERCAN, Gonca ALTINIŞIK İNAN, Hüseyin Furkan ÖZTÜRK

Comparison of Effectiveness of Radiation Therapy, Local Steroid Injection, and Extracorporeal Shock Wave Therapy in Patients with Plantar Fasciitis: A Multicenter Study

Özlem AYNACI, Emine CANYILMAZ, Osman AYNACI, Adnan YÖNEY, Ahmet Yaşar ZENGİN, Lasif SERDAR, Fatih CANYILMAZ, Emel HACIİSLAMOĞLU, Fatma ZENGİN

The Effects of Educational Levels on the Knowledge of Risk Factors and Awareness of Oral Cancer in a Turkish Population: A Cross-sectional Electronic Media Based Survey Study

Merva SOLUK TEKKEŞİN, Özkan ÇELİK, Işık İrem İNCEOĞLU, Dila Duygu SAC

Evaluation of Dose Distribution in Field Junction Area and Risk Organs for Supine and Prone Treatment Techniques in Craniospinal Irradiation

Murat KÖYLÜ, Deniz YALMAN, Yavuz ANACAK, İbrahim OLACAK, Serra KAMER, Onur ÜNLENEN, Nezahat OLACAK

Correlation between Decreased Nuclear Factor Kappa Beta (NFKβ), Kras, and Braf Genes’ Expression and Enhanced Chemosensitivity of Human Squamous Cell Carcinoma Cells to 5-fluorouracil and/or Mesenchymal Stem Cells-derived Microvesicles

Dina SABRY, Iman Mahmoud ABOUSHADY, Ghada Abdel Aziz ABDEL-LATİF, Sara El MOSHY