Ultrasonography-guided regional anesthesia (UGRA) applications are important in the practice of anesthesiology in the world. Despite the positive effect on patient care, there is concern that ultrasound (US) probes may be used repeatedly and assume a vector role in pathogen transport. There is no consensus on how to preserve US probes and use of gels against probing surface damage with pre-UGRA probe disinfection, agents used, and is still a research topic. Methods: Five different disinfection methods were compared via image quality by experienced anesthesiologists. Evaluators has been wanted to score the image that was recorded with using a defined disinfection method. Evaluators were blind while scoring the image. As a mean of 4,65 (US probe non-sterile stretch film coating and antiseptic spray(10% povidone-iodine) on the stretch film) Method 3 has been the most preferred one. The use of proven disinfection methods in UGRA interventions will be beneficial in terms of cost-effectiveness. According to study results, Method 3 (US probe non-sterile stretch film coating and antiseptic spray(10% povidone-iodine) on the stretch film) was observed to provide best image quality and cause the least cost for long-term use.
___
Yoshida T, Nakamoto T, Kamibayashi T. Ultrasound-guided obturator nerve block: a focused review on anatomy and updated techniques. Biomed Res Int. 2017;2017:7023750.
Bromberg AL, Dennis JA, Gritsenko K. Exparel/peripheral catheter use in the ambulatory setting and use of peripheral catheters postoperatively in the home setting. Curr Pain Headache Rep. 2017;21:13.
Volk T, Kubulus C. Regional anesthesia - are the standards changing? Anaesthesist. 2017;66:904-9.
Koköfer A, Nawratil J, Opperer M. Regional anesthesia for carotid surgery : An overview of anatomy, techniques and their clinical relevance. Anaesthesist 2017;66:283-90.
Sargin M, Sarıtas TB, Sarkilar G, ve ark.. Multi travmalı bir olguda infraklaviküler blok deneyimimiz. Bakırköy Tıp Dergisi. 2017;13:110-2.
Marhofer P, Schebesta K, Marhofer D. Hygiene aspects in ultrasound-guided regional anesthesia. Anaesthesist. 2016;65:492-8.
Fuzier R, Lammens S, Becuwe L, et al. The use of ultrasound in France: a point of view from experienced regional anesthesiologists. Acta Anaesthesiol Belg. 2016;67:9-15.
Amin V, Wilson D, Rouse G. USOFT: An ultrasound image analysis software for beef quality research. 1998.
Metcalfe SC, Evans JA. A study of the relationship between routine ultrasound quality assurance parameters and subjective operator image assessment. Br J Radiol. 1992;65:570-5.
Thijssen JM, Weijers G, de Korte CL. Objective performance testing and quality assurance of medical ultrasound equipment. Ultrasound Med Biol. 2007;33:460-71.
Koibuchi H, Fujii Y, Kotani K, et al. Degradation of ultrasound probes caused by disinfection with alcohol. J Med Ultrason. 2011;38:97-100.
Shokoohi H, Armstrong P, Tansek R. Emergency department ultrasound probe infection control: challenges and solutions. Open Access Emerg Med. 2015:7;1-9.
Mirza WA, Imam SH, Kharal MS, et al. Cleaning methods for ultrasound probes. J Coll Physicians Surg Pak. 2008;18:286-9.
Gharib M. A new and improved sterile ultrasound probe cover comprising two layers . United States Patent Application Publication, Pub. No.: US 2016/0135784, 2016.
Sharon M. “Cover for ultrasound probe.” U.S. Patent No. 6,132,378, 2000.
Taylor, RH. “Sterile drape for ultrasound probe.” U.S. Patent No. 4,887,615, 1989.