LOCKING PLATE VERSUS INTRAMEDULLARY DEVICE FIXATION FOR THE DISTAL METATARSAL CHEVRON OSTEOTOMY IN HALLUX VALGUS: A RETROSPECTIVE STUDY

Objective: Recently, an innovative intramedullary device was introduced for the fixation of the capital fragment in the distal metatarsal chevron osteotomy. The aim of the present study was to compare the outcomes of locking plate and intramedullary device fixation in the distal metatarsal chevron osteotomy in the surgical treatment of hallux valgus. Material and Methods: We reviewed 29 patients (29 feet) treated with distal metatarsal chevron osteotomies fixated by locking plate or intramedullary device for hallux valgus. Locking plate fixation were used for 14 patients (14 feet) and intramedullary device fixation were used for 15 patients (15 feet). Results: The mean follow-up period was 31 (6–56) months. The locking plate and intramedullary device groups did not differ significantly with respect to age, affected side, surgical time, duration of hospital stay, follow – up period or postoperative American Orthopedic Foot and Ankle Society scores (p>0.05). The hallux valgus angle and the intermetatarsal angle decreased significantly in both the locking plate and the intramedullary device groups (p

Halluks Valgus Cerrahisinde Distal Metatars Chevron Osteotomisinin Kilitli Plak ve İntramedüller Cihaz ile Tespitinin Karşılaştırılması: Retrospektif Bir Çalışma

Amaç: Yakın zamanda, distal metatars chevron osteotomisinin tespitinde kullanılmak üzere yeni bir intramedüller cihaz geliştirilmiştir. Çalışmamızın amacı halluks valgus cerrahisinde yapılan distal metatars chevron osteotomisinde, kilitli plak tespiti sonuçlarını intramedüller cihaz tespiti sonuçları ile karşılaştırmaktır. Gereç ve Yöntemler: Geriye dönük olarak, halluks valgus tedavisi için distal metatarsal chevron osteotomisi yapılmış ve kilitli plak veya intramedüller cihaz ile tespit edilmiş 29 hastanın 29 ayağı incelenmiştir. Kilitli plak ile tespit 14 hastada (14 ayakta) ve intramedüller cihaz tespit 15 hastada (15 ayakta) kullanılmıştır. Bulgular: Ortalama takip süresi 31 aydır (6–56). Kilitli plak ve intramedüller cihaz grupları arasında hastanın yaşı, ameliyat edilen taraf, ameliyat süresi, hastanede kalış süresi, takip süresi veya postop Amerikan Ortopedik Ayak ve Ayak Bileği Skoru (AOFAS) açısından anlamlı bir fark saptanmamıştır (p>0.05). Ameliyat sonrası dönemde halluks valgus açısı ve intermetatarsal açı ameliyat öncesi döneme göre her iki grupta da anlamlı bir şekilde azalmıştır (p0.05). Sonuç: Distal metatars chevron osteotomisinde hem kilitli plak hem de intramedüller cihaz tespitinin orta dereceli halluks valgusun cerrahi tedavisinde etkili olduğu bulunmuştur. Ancak hem kilitli plak hem de intramedüller cihaz tespitinin nispeten yüksek implant çıkarma oranları ile karakterize olduğu saptanmıştır.

___

1. Hecht PJ, Lin TJ. Hallux valgus. Med Clin North Am. 2014;98(2):227-32.

2. Smith BW, Coughlin MJ. Treatment of hallux valgus with increased distal metatarsal articular angle: Use of double and triple osteotomies. Foot Ankle Clin. 2009;14(3):369-82.

3. Komur B, Yilmaz B, Kaan E, Yucel B, Duymus TM, Ozdemir G, Guler O. Mid-term results of two different fixation methods for chevron osteotomy for correction of hallux valgus. J Foot Ankle Surg. 2018;57(5):904-9.

4. Matsumoto T, Gross CE, Parekh SG. Short-term radiographic outcome after distal chevron osteotomy for hallux valgus using intramedullary plates with an amended algorithm for the surgical management of hallux valgus. Foot Ankle Spec. 2019;12(1):25-33.

5. Palmanovich E, Myerson MS. Correction of moderate and severe hallux valgus deformity with a distal metatarsal osteotomy using an intramedullary plate. Foot Ankle Clin. 2014;19(2):191-201.

6. Austin DW, Leventen EO. A new osteotomy for hallux valgus: A horizontally directed “V” displacement osteotomy of the metatarsal head for hallux valgus and primus varus. Clin Orthop Relat Res. 1981;(157):25-30.

7. Andrews BJ, Fallat LM, Kish JP. Screw versus plate fixation for chevron osteotomy: A retrospective study. J Foot Ankle Surg. 2016;55(1):81-4.

8. Knecht JF, Van Pelt WC. Austin bunionectomy with kirschner wire fixation. J Am Podiatry Med Assoc. 1981;71(3):139-44.

9. Kissel CG, Unroe BJ, Parker RM. The offset “V” bunionectomy using cortical screw and buried Kirschner wire fixation. J Foot Ankle Surg. 1992;31(6):560-77.

10. Quinn MR, Di Stazio J, Kruljac SJ. Herbert bone screw fixation of the Austin bunionectomy. J Foot Surg. 1987;26(6):516-9.

11.Barca F, Busa R. Austin/chevron osteotomy fixed with bioabsorbable poly-L-lactic acid single screw. J Foot Ankle Surg. 1997;36(1):15-20.

12. Winemaker MJ, Amendola A. Comparison of bioabsorbable pins and Kirschner wires in the fixation of chevron for hallux valgus. Foot Ankle Int. 1996;17(10):623-8.

13.Buckenberger RK, Goldman FD. Chevron bunionectomy fixation: in vitro stability assessment of plate-and-screw system compared with Kirschner wire. J Foot Ankle Surg. 1995;34(3):266- 72.

14. Yearian PR, Brown T, Goldman FD. Chevron bunionectomy with microplate and screw fixation: a retrospective follow-up of 26 feet. J Foot Ankle Surg. 1996;35(6):532-6.

15.Bennett GL, Sabetta JA. Evaluation of an innovative fixation system for chevron bunionectomy. Foot Ankle Int. 2016;37(2):205-9.

16. Hallux Osteotomy Locking Plate (ITS GmbH, Austria) Official Brochure. Date of acces: 04.10.2018: http://www.itsimplant.com/images/pdfs/en/HOL_en.pdf.

17. Mini maxlock extreme™ (Wright Medical Group N.V., USA) Official Brochure. Date of acces: 04.10.2018: http://www.wmtemedia.com/ProductFiles/Files/PD Fs/SET-604-017_EN_LR_LE.pdf.

18. Windhagen H, Radtke K, Weizbauer A, Diekmann J, Noll Y, Kreimeyer U et al. Biodegradable magnesium-based screw clinically equivalent to titanium screw in hallux valgus surgery: short term results of the first prospective, randomized, controlled clinical pilot study. Biomed Eng Online. 2013;12(1):62-8.
Kırıkkale Üniversitesi Tıp Fakültesi Dergisi-Cover
  • ISSN: 2148-9645
  • Yayın Aralığı: Yılda 3 Sayı
  • Başlangıç: 1999
  • Yayıncı: KIRIKKALE ÜNİVERSİTESİ KÜTÜPHANE VE DOKÜMANTASYON BAŞKANLIĞI
Sayıdaki Diğer Makaleler

Halluks Valgus Cerrahisinde Distal Metatars Chevron Osteotomisinin Kilitli Plak ve İntramedüller Cihaz ile Tespitinin Karşılaştırılması: Retrospektif Bir Çalışma

Ubeydullah SEVGİLİ, Ahmet Sinan SARI, Özgün KARAKUŞ

TİROİD İNCE İĞNE ASPİRASYON BİYOPSİLERİ İLE HİSTOPATOLOJİ SONUÇLARININ KARŞILAŞTIRILMASI

Tuba DEVRİM, Mahi BALCI

İNME, SPİNAL KORD YARALANMASI VE SEREBRAL PALSİ HASTALARINDA ALT EKSTREMİTE ORTEZ KULLANIMINI ETKİLEYEN NEDENLER

Turgut KÜLTÜR, Gizem SUNA

LOCKING PLATE VERSUS INTRAMEDULLARY DEVICE FIXATION FOR THE DISTAL METATARSAL CHEVRON OSTEOTOMY IN HALLUX VALGUS: A RETROSPECTIVE STUDY

Ahmet Sinan SARI, Ubeydullah SEVGİLİ, Özgün KARAKUŞ

Safra Taşı İleusu Değerlendirmesinde Radyolojik Görüntülemenin Klinik Faydası

Adnan ÖZDEMİR, Yunus YILMAZSOY, Serdar ARSLAN, Faruk PEHLİVANLI

DİZ OSTEOARTRİTİ TEDAVİSİNDE KOMBİNE FİZİK TEDAVİ VE KAPLICA TEDAVİSİNİN ETKİNLİĞİ

Şahika Burcu KARACA, Nursel DOĞANYİĞİT KUZAN

İdiyopatik Karpal Tünel Sendromlu Hastalarda Tedavi Öncesi ve Sonrası MRG Bulguları

Şahika Burcu KARACA, Rula ŞAHİN, Leman GÜNBEY KARABEKMEZ, Tevfik YETİŞ, Nihal DURAN

Acil Servise Künt Toraks Travması ile Başvuran Hastalarda Pnömotoraks, Kosta Kırıkları ve Hemotoraks’ın Değerlendirilmesinde Ultrasonografinin Etkinliği

Halil ÇETİNKAYA, Yücel YÜZBAŞIOĞLU, Mehmet Akif KARAMERCAN, Yavuz KATIRCI, Meral TANDOĞAN, Figen COŞKUN

5-FLOROURACİL VE RESVERATROL KOMBİNASYONUNUN İNSAN AKCİĞER KANSERİ A549 HÜCRE HATTINDA APOPTOZİS ÜZERİNE ETKİSİ

Can Ali AĞCA, Mahinur, Abdurrahman CAN, Yeşim YUMAK

NONFONKSİYONE ADRENAL İNSİDENTALOMALARDA İNSULİN REZİSTANSI VE YENİ İNFLAMATUAR BELİRTEÇLER

Zehra AKGÜN, Aşkın GÜNGÜNEŞ, Şenay DURMAZ