Comparison of Refractive Values Measured by Plusoptix A09 Photorefractometer and Standard Autorefractometer in Adults

Comparison of Refractive Values Measured by Plusoptix A09 Photorefractometer and Standard Autorefractometer in Adults

Purpose: To compare the refraction values obtained with Plusoptix A09 photorefractometer and Topcon autorefractometer in adults. Materials and Methods: 230 eyes of 115 patients who had no eye disease other than refractive error were included in the study. Refraction measurements were made with Plusoptix A09 photorefractometer and Topcon KR-8100P autorefractometer devices. Measurements were taken 3 times and the averages were recorded. Median spherical, cylindrical, spherical equivalent and cylindrical axis measurements obtained with both devices were statistically compared. Interdevice compatibility was evaluated with intraclass correlation coefficient (ICC) and Spearman correlation analysis. Results: The median age of 115 patients included in the study was 37 years (range, 20-67), and 50 (43.5%) were female and 65 (56.5%) were male. Median spherical value obtained with Plusoptix A09 photorefractometer 0.50 D (range, -4.00-(3.25)), median cylindrical value -0.50 D (range, -2.00-(0.00)), spherical equivalent median 0.38 D (range, -4.00- (3.00)), the J0 power median was 0 (range, -1.00-(1.00)), and the J45 power median was 0 (range, -0.49-(0.37)). The median of the spherical value obtained by autorefractometer is 0.0 D (range, -3.75-(2.00)), the median of the cylindrical value is -0.50 D (range, -2.00-(0)), the median of the spherical equivalent is -0.25 D (range, -3.75- (1.75)), the J0 power median was 0 (range, -0.87-(0.98)), and the J45 power median was 0 (range, -0.59-(0.50)). There was a significant difference between spherical, cylindrical and spherical equivalent measurements between devices. There was no significant difference between J0 and J45 measurements. Conclusion: Besides being used in childhood, Plusoptix A09 photorefractometer can also be used as a fast and easy refraction measurement method, especially in physically or mentally handicapped adults with adjustment problems.

___

  • 1. Dandona R, Dandona L: Refractive error blindness. Bull World Health Organ. 2001, 79: 237-243.
  • 2. Resnikoff S, Pascolini D, Mariotti SP, Pokharel GP. Global magnitude of visual impairment caused by uncorrected refractive errors in 2004. Bull World Health Organ. 2008; 86:63-70.
  • 3. Rassow B, Wesemann W. Automatic infrared refractors--1985. Ophthalmology 1985; 92(8 Suppl):20-33.
  • 4. Schimitzek T, Haase W. Efficiency of a video-autorefractometer used as a screening device for amblyogenic factors. Graefes Arch Clin Exp Ophthalmol 2002; 240:710–6
  • 5. . Choi M, Weiss S, Schaeffel F, Seidemann A, Howland HC, Wilhelm B, et al. Laboratory, clinical, and kindergarten test of a new eccentric infrared photorefractor (PowerRefractor). Optom Vis Sci 2000; 77(10):537-48.
  • 6. Abrahamsson M, Ohlsson J, Björndahl M, Abrahamsson H. Clinical evaluation of an eccentric infrared photorefractor: the PowerRefractor. Acta Ophthalmol Scand 2003; 81(6): 605-10.
  • 7. Allen PM, Radhakrishnan H, O’Leary DJ. Repeatability and validity of the PowerRefractor and the Nidek AR600-A in an adult population with healthy eyes. Optom Vis Sci 2003; 80(3): 245-51.
  • 8. Demirel S. Bilak S, Yuvacı I, Cumurcu T, Colak C. Objective measurement of refractive errors: Comparison of Plusoptix S08 with a standard autorefratometer. J Clin Exp Invest 2013; 4(1):40-6.
  • 9. Arıcı C, Türk A, Ceylan OM, Mutlu FM, Altınsoy Hİ. [Comparison of refractive errors measured by Plusoptix S08, potec PRK6000 and Nidek ARK-30 hand-held autorefractometer in school-age children and adult population]. Turk J Ophthalmol 2010; 40(6): 328-32.
  • 10. Acar E. D, Acar U, Tunay Ö. Z, Özdemir Ö, Dolgun B. AN,. Comparison of refractive errors measured by plusoptix A09 photorefractometer and a standart autorefractometer in adult population. Turkiye Klinikleri J ophthalmol 2016; 25(2):100-4
  • 11. Choi M, Weiss S, Schaeffel F, Seidemann A, Howland HC, Wilhelm B, et al. Laboratory, clinical, and kindergarten test of a new eccentric infrared photorefractor (PowerRefractor). Optom Vis Sci 2000; 77(10):537-48.
  • 12. Güler E, Yağcı R, Balcı M, Aydoğdu FB, Hepşen İF. [Evaluation of photorefraction and autorefraction measurements in adult population and children]. Yeni Tıp Dergisi 2012; 29(2):84- 7.
  • 13. Ayse YK, Onder U, Suheyla K. Accuracy of Plusoptix S04 in children and teens. Can J Ophthalmol 2011; 46(2):153-7.
  • 14. Anayol MA, Yılmazoğlu MÖ, Yılmazbaş P, Tırhış H, Öztürk F. [Comparison of Plusoptix S08 photorefractometer with Canon RK-F1 autorefractokeratometer in assessment of refractive errors in ındividuals aged 3 to 19 years]. Turkiye Klinikleri J Ophthalmol 2013; 22(3):163-7.
Journal of Experimental and Clinical Medicine-Cover
  • Yayın Aralığı: Yılda 4 Sayı
  • Başlangıç: 1980
  • Yayıncı: Ondokuz mayıs Üniversitesi Tıp Fakültesi
Sayıdaki Diğer Makaleler

Investigation of relationship between nesfatin's, chemerin's, apelin's levels and insulin resistance and metabolic syndrome in Polycystic Ovary Syndrome patients

Ömer ÜNAL, Ozan KARADENİZ, Zehra KURDOGLU

Which one to choose for anti-cytokeratin immunohistochemistry in small gastric biopsies: Bleached Periodic acid schiff- Alcian blue (PAB) or May Grunwald Giemsa (MGG) sections?

Yasemen ADALI, Hatice BEŞEREN

Utility of preoperative neutrophil–lymphocyte and platelet–lymphocyte ratios in differential diagnosis of benign, borderline, and malignant ovarian tumors

Sahra Sultan KARA, Esra KELES, Derya SİVRİ AYDIN, Emre MAT, Gazi YILDIZ, Rezzan Berna TEMOÇİN, Pınar BİROL, Pınar YILDIZ

The comparison of PAP smear test results of women according to anti mullerian hormone levels

İnci ÖZ, Asena AYAR MADENLİ, Ergül DEMİRÇİVİ

Alginate-based hydrogel promotes neuronal survival and axon outgrowth of neuron-like cells

Başak DALBAYRAK, Ekin SÖNMEZ, Habibe KURT, Müge İŞLETEN HOŞOĞLU, N. Hale SAYBASİLİ, Işıl AKSAN KURNAZ

Comparison of Refractive Values Measured by Plusoptix A09 Photorefractometer and Standard Autorefractometer in Adults

Mustafa DURAN, Konuralp YAKAR, Emrah KAN

Health anxiety, somatosensory amplification, and perceived social support levels in patients scheduled for hysteroscopy

Filiz ÖZSOY, Seda UYSAL, Kaaan Eray UZUN, Orhan ULUSOY, Şuheda KAYA, Nülüfer KILIÇ, Zeki ÖZSOY

The effect of onion juice on menstrual disorder and hormonal parameters in patients with polycystic ovary syndrome

Ayşe Şeyma KÜÇÜKAKÇA

Examining the correlation between fear of COVID-19, sexual functions, depression, and anxiety in the women who underwent COVID-19

Özlem ÇINAR ÖZDEMİR, Betül YILDIRIM, Kübra ÖZONAY

Retrospective analysis of bacterial agents in central nervous system infections: A nine-years evaluation in a university hospital

Ayşe İSTANBULLU, Serhat SİREKBASAN, Mehmet DEMİRCİ