Performance of PV grid-connected system under grid failure

Performance of PV grid-connected system under grid failure

A great deal of research is being carried out to ameliorate the performance of grid-connected photovoltaic (PV) systems. This paper shoes the performance of a 1kW PV grid-connected system under grid failure. Among grid faults, the cases of islanding and grid voltage sags are tested with the proposed system. Hysteresis current control combined with active Islanding Detection Methods (IDMs) is developed to determine the effectiveness of the single phase full bridge inverter to detect islanding. Single Phase Induction Motor (SPIM) is taken as local load to shoes the effects of grid voltage sags with different depths and durations. A Theoretical, simulations, and experimental result shoes the performance of the proposed system.

___

  • European Photovoltaic Industry Association (EPIA), Market Report 2011.
  • IEEE Standard for Interconnecting Distributed Resources with Electric Power Systems, IEEE Std 1547.2-2008.
  • M. G. Villalva, J. R. Gazoli, E. Ruppert, “ Modelling and circuit-based
  • Brazilian Journal of Power Electronics, 2009, vol. 14, no. 1, ISSN 1414-8862, pp. 35-45.
  • M. Trabelsi, M. Brahim, K.A Ghazi, L. Ben-Brahim, S. Al-Dosari, J. Belhadj “A new design of predictive controller combined with an islanding detection method for a grid connected Photovoltaic Power Conditioning System” International Renewable Energy Congress, Tunisia, December 2011, pp.352-358.
  • M. Xu, R.V.N. Melnik, U. Borup, “Modeling anti- islanding protection devices for photovoltaic systems”, Elsevier on Renewable Energy 29 (2004), pp. 2195-2216. [6] L.A.C. Lopes, H. Sun, “Performance assessment of active frequency drifting islanding detection methods”, IEEE Transaction on Energy Conversion,Vol.21, No.1, March 2006, pp. 171-180.
  • Z. Ye, A. Kowalkar, Y. Zhang, P. Du, and R.Walling, “Evaluation of anti-islanding schemes based on non- detection zone concept,” IEEE Trans. Power Electron. (2004), vol. 19, no. 5, pp. 1171-1176.
  • M.E. Ropp, M. Begovic, A. Rohatgi, “Determining the Relative Effectiveness of Islanding Detection Methods Using Phase Criteria and Non-detection Zones”, IEEE Transactions on Energy Conversion, Vol. 15, No. 3, September 2000, pp. 290-296.
  • M. H. J. Bollen “Understanding Power Quality Problems. Voltage sags and interruptions”, IEEE Press Series on Power Engineering, 2000, ISBN 0-7803- 4713-7. [10]
  • S.B.Kjaer, J. K. Pedersen, and F. Blaabjerg, “A Review of Single-Phase Grid-Connected Inverters for Photovoltaic Modules”, IEEE Transaction On Industry Applications”, Vol. 41, No. 5, September/October 2005, pp . 1292-1306. [11]
  • F. Blaabjerg, R. Teodorescu, M. Liserre, and A.V. Timbus,” Overview of Control and Grid Synchronization for Distributed Power Generation Systems”, IEEE Transaction on Industrial Electronics, Vol. 53, No. 3, June 2001, pp. 594-601. [12]
  • R.A. Mastromauro, M. Liserre, T. Kerekes, and A. Aquila “ A Single-Phase Voltage-Controlled Grid- Connected Photovoltaic System With Power Quality Conditioner Functionality”, IEEE Transaction on Industrial Electronics, Vol. 56, No. 11, November 2009, pp. 4436-4444. [13]
  • J. H. R. Enslin, M. S.Wolf, D. B. Snyman, andW. Sweigers,” Integrated photovoltaic maximum power point tracking converter”, IEEE Transaction on Industrial Electronics, vol. 44 , Dec. 1997, pp. 769-773. [14]
  • M.F.McGranaghan, D.R. Mueller, M.J.Samotyj,” Voltage sags in industrial systems” IEEE Transaction On Industry Applications, Vol. 29, No 2, Mars-April 1993, pp.397-403. [15]
  • J.-W. Choi, Y.-K. Kim and H.-G. Kim, “Digital PLL control for single-phase photovoltaic system,” Proc. IEEE, Elect. Power Appl., Vol. 153, No. 1, Jan. 2006, pp. 40-46. [16]
  • L. Asiminoaei, R.Teodorescu, F. Blaabjerg, and U. Borup,” Implementation and Test of an Online Embedded Grid Impedance Estimation Technique for PV Inverters” IEEE Transaction on Industrial Electronics, Vol. 52, No. 4, August 2005, pp. 1136-1144.
International Journal Of Renewable Energy Research-Cover
  • ISSN: 1309-0127
  • Başlangıç: 2015
  • Yayıncı: İlhami ÇOLAK
Sayıdaki Diğer Makaleler

Assessment of Wind Energy Potential Based on Metar Data in Malaysia

Aliashim Albani, Mohd Zamri Bin Ibrahim, M. H.M Hamzah

A Microcontroller-Based Active Solar Water Heating System for Domestic Applications

İshioma Ani ODİGWE, Oluwakorede Olakunle OLOGUN, Oluwaseyi OLATOKUN, Awelewa Ajibola AYOKUNLE, Ayoade Felix AGBETUYİ, Samuel Adekunle ISAAC

Analysis of Wind Power Potential Characteristics and Feasibility in Kuwait for Possible Electricity Production

Ali HAJİAH, M. SEBZALİ, S. EBRAHİM

Optimal Power Flow Management Control for Grid Connected Photovoltaic/Wind turbine/Diesel generator (GCPWD) Hybrid System with Batteries

Bala MURUGAN, Manoharan S.

Effect of Dust Deposition on the Performance of Multi-Crystalline Photovoltaic Modules Based on Experimental Measurements

Tamer KHATİB, Hussian KAZEM, K. SOPİAN, Frank BUTTİNGER, Wilfried ELMENREİCH, Ahmed Said ALBUSAİDİ

Investigation of Waste Coffee Ground as a Potential Raw Material for Biodiesel Production

Mebrahtu Haile BERHE, Araya ASFAW, Nigist ASFAW

Biomass Yield Potential of Paulownia Trees in a Semi-Arid Mediterranean Environment (S Spain)

Victor Hugo Duran Zuazo, Juan Antonio Jiménez Bocanegra, Francisco Perea Torres, Carmen Rocío Rodríguez Pleguezuelo, José Ramón Francia Martínez

Control of Real and Reactive Power using a Novel SVC Feedback System for Load Sharing in Grid Connected PV Power System

Md. Habib Ullah, S.M. Ehsanul Haque

Efficient Modeling, Control and Optimization of Hybrid Renewable-Conventional Energy Systems

Ahmed Abdallh, Bart Heyrman, Luc Dupré

Design of a Photovoltaic Powered Forced Convection Solar Dryer in NEH Region of India

Mahendra Singh Seveda