Performance of PV grid-connected system under grid failure

Performance of PV grid-connected system under grid failure

A great deal of research is being carried out to ameliorate the performance of grid-connected photovoltaic (PV) systems. This paper shoes the performance of a 1kW PV grid-connected system under grid failure. Among grid faults, the cases of islanding and grid voltage sags are tested with the proposed system. Hysteresis current control combined with active Islanding Detection Methods (IDMs) is developed to determine the effectiveness of the single phase full bridge inverter to detect islanding. Single Phase Induction Motor (SPIM) is taken as local load to shoes the effects of grid voltage sags with different depths and durations. A Theoretical, simulations, and experimental result shoes the performance of the proposed system.

___

  • European Photovoltaic Industry Association (EPIA), Market Report 2011.
  • IEEE Standard for Interconnecting Distributed Resources with Electric Power Systems, IEEE Std 1547.2-2008.
  • M. G. Villalva, J. R. Gazoli, E. Ruppert, “ Modelling and circuit-based
  • Brazilian Journal of Power Electronics, 2009, vol. 14, no. 1, ISSN 1414-8862, pp. 35-45.
  • M. Trabelsi, M. Brahim, K.A Ghazi, L. Ben-Brahim, S. Al-Dosari, J. Belhadj “A new design of predictive controller combined with an islanding detection method for a grid connected Photovoltaic Power Conditioning System” International Renewable Energy Congress, Tunisia, December 2011, pp.352-358.
  • M. Xu, R.V.N. Melnik, U. Borup, “Modeling anti- islanding protection devices for photovoltaic systems”, Elsevier on Renewable Energy 29 (2004), pp. 2195-2216. [6] L.A.C. Lopes, H. Sun, “Performance assessment of active frequency drifting islanding detection methods”, IEEE Transaction on Energy Conversion,Vol.21, No.1, March 2006, pp. 171-180.
  • Z. Ye, A. Kowalkar, Y. Zhang, P. Du, and R.Walling, “Evaluation of anti-islanding schemes based on non- detection zone concept,” IEEE Trans. Power Electron. (2004), vol. 19, no. 5, pp. 1171-1176.
  • M.E. Ropp, M. Begovic, A. Rohatgi, “Determining the Relative Effectiveness of Islanding Detection Methods Using Phase Criteria and Non-detection Zones”, IEEE Transactions on Energy Conversion, Vol. 15, No. 3, September 2000, pp. 290-296.
  • M. H. J. Bollen “Understanding Power Quality Problems. Voltage sags and interruptions”, IEEE Press Series on Power Engineering, 2000, ISBN 0-7803- 4713-7. [10]
  • S.B.Kjaer, J. K. Pedersen, and F. Blaabjerg, “A Review of Single-Phase Grid-Connected Inverters for Photovoltaic Modules”, IEEE Transaction On Industry Applications”, Vol. 41, No. 5, September/October 2005, pp . 1292-1306. [11]
  • F. Blaabjerg, R. Teodorescu, M. Liserre, and A.V. Timbus,” Overview of Control and Grid Synchronization for Distributed Power Generation Systems”, IEEE Transaction on Industrial Electronics, Vol. 53, No. 3, June 2001, pp. 594-601. [12]
  • R.A. Mastromauro, M. Liserre, T. Kerekes, and A. Aquila “ A Single-Phase Voltage-Controlled Grid- Connected Photovoltaic System With Power Quality Conditioner Functionality”, IEEE Transaction on Industrial Electronics, Vol. 56, No. 11, November 2009, pp. 4436-4444. [13]
  • J. H. R. Enslin, M. S.Wolf, D. B. Snyman, andW. Sweigers,” Integrated photovoltaic maximum power point tracking converter”, IEEE Transaction on Industrial Electronics, vol. 44 , Dec. 1997, pp. 769-773. [14]
  • M.F.McGranaghan, D.R. Mueller, M.J.Samotyj,” Voltage sags in industrial systems” IEEE Transaction On Industry Applications, Vol. 29, No 2, Mars-April 1993, pp.397-403. [15]
  • J.-W. Choi, Y.-K. Kim and H.-G. Kim, “Digital PLL control for single-phase photovoltaic system,” Proc. IEEE, Elect. Power Appl., Vol. 153, No. 1, Jan. 2006, pp. 40-46. [16]
  • L. Asiminoaei, R.Teodorescu, F. Blaabjerg, and U. Borup,” Implementation and Test of an Online Embedded Grid Impedance Estimation Technique for PV Inverters” IEEE Transaction on Industrial Electronics, Vol. 52, No. 4, August 2005, pp. 1136-1144.
International Journal Of Renewable Energy Research-Cover
  • ISSN: 1309-0127
  • Başlangıç: 2015
  • Yayıncı: İlhami ÇOLAK
Sayıdaki Diğer Makaleler

Dependence of Silicon Heterojunction Solar Cell Performance on Surface Preparation, Deposition Conditions, Chemical Treatment and Annealing

Sandeep CHANDRİL, Manish PATHAK, Vinayan BHARDWAJ, Abhishek SHARAN, Nishi CHAHAR, Son Pal SİNGH, Anil Kumar SAXENA, Sudip BHATTACHARYA

Analysis of Wind Power Potential Characteristics and Feasibility in Kuwait for Possible Electricity Production

Ali HAJİAH, M. SEBZALİ, S. EBRAHİM

Investigation of Waste Coffee Ground as a Potential Raw Material for Biodiesel Production

Mebrahtu Haile BERHE, Araya ASFAW, Nigist ASFAW

Efficient Modeling, Control and Optimization of Hybrid Renewable-Conventional Energy Systems

Ahmed Abdallh, Bart Heyrman, Luc Dupré

Potentials of Optimized Hybrid System in Powering Off-Grid Macro Base Transmitter Station Site

Vincent Anayochukwu ANİ, Anthony Ndubueze NZEAKO

Assessment of Wind Energy Potential Based on Metar Data in Malaysia

Aliashim Albani, Mohd Zamri Bin Ibrahim, M. H.M Hamzah

A Feasibility Study of Solar-Wind-Diesel Hybrid System in Rural and Remote Areas of Bangladesh

Molla Shahadat Hossain Lipu, Md. Shazib UDDİN, Muhammad Ahad Rahman Miah

Optimal Power Flow Management Control for Grid Connected Photovoltaic/Wind turbine/Diesel generator (GCPWD) Hybrid System with Batteries

Bala MURUGAN, Manoharan S.

Assesment of Carbon Credits for Power Generation Systems at GSM Base Station Site

Vincent Anayochukwu Ani, Emmanuel Onyeka Ani

Improved Control of Concentration Boundary Layer in Microfluidic Fuel Cells

Razieh Hassanshahi, M. Fathipour