Developing of a Virtual MCA to Acquire a Radiation Spectrum

Developing of a Virtual MCA to Acquire a Radiation Spectrum

A virtual MCA (Multichannel Analyzer) was developed via a software in the computerenvironment to display a spectrum for radiation detection experiments. A pulse generator thatsubstitutes for a particle detector was used to supply the signals to be analyzed in the MCA. Thepulses from the generator were analyzed by a virtual MCA and a real MCA. Channel numbersand the number of counts in these channels, and the total counts obtained from the virtual MCAand the real MCA were compared with each other. For comparing of the number of counts, datawere accumulated in different acquisition times. After comparison of the results, it wasobserved that the virtual MCA was quite successful as well as a real MCA. It was concludedfrom the introduced work that the developed virtual MCA would be able to use in a radiationdetection system like a real one.

___

  • [1] Sumathi, S.,& Surekha, P. (2007). LabVIEW based advanced instrumentation systems. Berlin: Springer.
  • [2] Jerome, J. (2010). Virtual instrumentation using LabVIEW. New Delhi: PHI Learning Private Limited.
  • [3] NI, “Virtual Instrumentation”, https://www.ni.com/en-tr/innovations/white-papers/06/virtualinstrumentation.html, Accessed: 17/03/2021. [4] Folea, S. (2011). LabVIEW-practical applications and solutions: Application of virtual instrumentation in nuclear physics experiments (Jiri Pechousek). Croatia: InTech.
  • [5] Tooley, M. (2005). PC based instrumentation and control (Third edition). Burlington: Elsevier.
  • [6] Ramachandiran, G., Kandhasamy, J.,& Saminathan, A. (2020).Virtual instrumentation in electrical engineering applications. J. Inst. Eng. India Ser. B, 101, 193-199.https://doi.org/10.1007/s40031-020- 00437-w
  • [7] Mâțiu-Iovan, L., Ordodi, V., Ionel, R.,& Bonciog, D. (2020). Virtual instrumentation based prototype for evaluation of the cardiac systolic function. 2020 International Symposium on Electronics and Telecommunications (ISETC), 1-4.doi:10.1109/ISETC50328.2020.9301047
  • [8] Aswale, P. S. (2020).Teaching-learning process in engineering using virtual instrument based on LABVIEW. IJETT, 7(1), 15006-15008.
  • [9] Leo, W. R. (1987). Techniques for nuclear and particle physics experiments. Berlin: Springer-Verlag.
  • [10] ORTEC, “Pulse-Height, Charge, or Energy Spectroscopy”, https://www.ortec-online.com/- /media/ametekortec/research-electronics-applications/pulse-height-charge-energyspectroscopy.pdf?dmc=1&la=en&revision=dc127fad-999f-4b76-b190- c5f37964061a&hash=E49B7ACCA956E39AC647869BC1E4C0F3, Accessed: 17/03/2021.
  • [11] Newton, F., Ghadigaonkar, V.,& D’souza, C. (2015).Multichannel pulse height analyser using FPGA for data acquisition. International Journal of Students Research in Technology & Management, 3(05), 363-364.
  • [12] Ibrahim, M. M., Yussup, N., Lombigit, L., Rahman, N. A. A.,& Jaafar, Z.(2014). Development of multichannel analyzer using sound card ADC for nuclear spectroscopy system. AIP Conf. Proc., 1584, 50-53.doi: 10.1063/1.4866103
  • [13] Cao, H. R., Wang, H. X., Zheng, Y. Y. et al. (2020). Development of digital multi-channel and timedivision pulse height analyzer based on PXIE bus for hard X-ray diagnostic in East. Instrum Exp Tech, 63, 453-460. https://doi.org/10.1134/S002044122004003X
  • [14] Liu, Y., Xiong, H., Dong, C., Zhao, C., Zhou, Q.,& Li, S. (2020). Real-time signal processing in field programmable gate array based digital gamma-ray spectrometer. Rev. Sci. Instrum., 91, 104707.https://doi.org/10.1063/5.0005694
  • [15] Susanto, A. T. et al. (2020). A systematic literature reviews of multichannel analyzer based on FPGA for gamma spectroscopy. J. Phys.: Conf. Ser., 1528, 012016.doi:10.1088/1742-6596/1528/1/012016
  • [16] Kim, B. J. et al.(2020). Design of optimal digital filter and digital signal processing for a CdZnTe high resolution gamma-ray system. Applied Radiation and Isotopes, 162, 109171. https://doi.org/10.1016/j.apradiso.2020.109171
  • [17] Mitra, P. et al. (2021). An environmental gamma spectrometry system with CsI(Tl) scintillator and FPGA based MCA for open field deployment. Applied Radiation and Isotopes, 172, 109677. https://doi.org/10.1016/j.apradiso.2021.109677
  • [18] Thuraka, E. R., Ganesh, R., Prakash, D. B. et al. (2021). Digital multi-channel analyzer for detection and analysis of radiation in nuclear spectroscopy. Materials Today: Proceedings, 38, 3160-3167. https://doi.org/10.1016/j.matpr.2020.09.580
  • [19] ORTEC, “419 Precision Pulse Generator”, https://www.ortec-online.com/products/electronics/pulsegenerator/419, Accessed: 17/03/2021.
  • [20] Bryn Mawr College, “Model 485 Amplifier Operating and Service Manual”, http://bascom.brynmawr.edu/physics/courses/phys331/resource/manuals/ortec_485_amplifier.pdf, Accessed: 17/03/2021.
  • [21] NI, “Execution Structures in LabVIEW”, https://www.ni.com/getting-started/labviewbasics/execution-structures, Accessed: 17/03/2021.
  • [22] NI, “Accuracy of Software-Timed Applications in LabVIEW”, https://knowledge.ni.com/KnowledgeArticleDetails?id=kA00Z000000P9QiSAK&l=en-TR, Accessed: 17/03/2021.