A Novel Biosensor Based on Laccase for The Detection of Catechol

A Novel Biosensor Based on Laccase for The Detection of Catechol

Phenolic compounds are broadly used in petrol industrial production processes and thus they arehazardous for ground and surface water and environment. Many of them have harmful effects onplants, animals and human health. Laccases can oxide phenol and phenolic compounds. Biosensorsprovide ideal sensing systems to determine phenolic compounds. In the present paper, it wasdeveloped novel sensor surface with modified laccase on gold electrode which could recognize thephenolic compound catechol. The electrode arrays integrated microfluidics have been fabricated andcharacterized in order to create a sensor chip which is easy, rapid, and cheaper to produce also havegood electrochemical sensing properties. This gold electrode was used to obtain laccase activesurface. Laccase was covalently bounded to self-assembled monolayer on gold electrode viaglutaraldehyde reactions. Cyclic voltammetry and amperometry activity assays showed that thedetection of catechol with laccase modified gold surface. All of the study was carried out usingautomated biosensor device. Linear range for this biosensor was 0.025 mM to 0.8 mM.

___

  • 1. Khan, R, Dey, NC, Hazarika, AK, Saini, KK, Dhayal, M. 2011. Mycotoxin detection on antibody-immobilized conducting polymer-supported electrochemically polymerized acacia gum. Analytical Biochemistry; 410: 2,185-190.
  • 2. Cai, H, Cao, X N, Jiang, Y, He, P G, Fang, Y Z. 2003. Carbon nanotube-enhanced electrochemical DNA biosensor for DNA hybridization detection. Analytical and Bioanalytical Chemistry; 375: 287-293.
  • 3. Li, Y, Liu, X, Lin, Z. 2012. Recent developments and applications of surface plasmon resonance biosensors for the detection of mycotoxins in foodstuffs. Food Chemistry. 132: 1549-1554.
  • 4. Trietsch, SJ, Hankemeier, T, Linden, HJ. 2011. Lab-on-a-chip technologies for massive parallel data generation in the life sciences: A review. Chemometrics and Intelligent Laboratory Systems; 108: 64-75.
  • 5. Chang, HS, Choo, KH, Lee, B, Choi, SJ. 2009. The methods of identification analysis, and removal of endocrine disrupting compounds (EDCs) in water. Journal of Hazardous Materials; 172: 1–12.
  • 6. Sungur S, Koroglu M, Ozkan A. 2014. Determinatıon of bisphenol A migrating from canned food and beverages in markets. Food Chemistry; 142: 87-91.
  • 7. Tepe HD. 2019. Qualitative Analysis of Alfalfa Seed Methanol Extract by GC-MS and Determination of Antioxidant Properties. Celal Bayar University Journal of Science; 15:2, 175-180.
  • 8. Diaconu M, Litescu SC, Radu GL. 2010 Laccase–MWCNT– chitosan biosensor – A new tool for total polyphenolic content evaluation from in vitro cultivated plants. Sensors and Actuators B Chemical; 145: 800–806.
  • 9. Roy JJ, Abraham TE, Abhijith KS, Kumar PVS, Thakur MS. 2005. Biosensor for the determination of phenols based on cross-linked enzyme crystals (CLEC) of laccase. Biosensors Bioelectronics. 21: 206–211.
  • 10. Chawla S, Rawal R, Kumar D, Pundir CS. 2012. Amperometric determination of total phenolic content in wine by laccase immobilized onto silver nanoparticles/zinc oxide nanoparticles modified gold electrode. Analytical Biochemistry; 430:16–23.
  • 11. Chawla S, Rawal R, Pundir CS. 2011 Fabrication of polyphenol biosensor based on laccase immobilized on copper nanoparticles /chitosan/multiwalled carbon nanotubes/polyaniline-modified gold electrode. Journal of Biotechnology; 156: 39–45.
  • 12. Quan D, Kim Y, Shin W. 2004 Sensing characteristics of tyrosinase immobilized and tyrosinase, laccase co-immobilized platinum electrodes. Bulletin Korean Chemical Society; 25: 1195–1201.
  • 13. Leite OD, Fatibello-filho O, Barbosa ADM. 2003. Determination of catecholamines in pharmaceutical formulations using a biosensor modified with a crude extract of fungi laccase (Pleurotus ostreatus). Journal of Brazilian Chemical Society; 14: 297–303.
  • 14. Wilkołazka AJ, Ruzgas T, Gorton L. 2005. Amperometric detection of mono and diphenols at Cerrena unicolor laccasemodified graphite electrode: correlation between sensitivity and substrate structure. Talanta; 66: 1219–1224.
  • 15. Haghighi B, Gorton L, Ruzgas T, Jonsson LJ. 2003. Characterization of graphite electrodes modified with laccase from Trametes versicolor and their use for bioelectrochemical monitoring of phenolic compounds in flow injection analysis. Analytical Chim. Acta; 487: 3–14.
  • 16. Litescu SC, Eremia SAV, Bertoli A, Pistelli L, Radu GL. 2010. Laccase-nafion based biosensor for the determination of polyphenolic secondary metabolites. Analytical Letters; 43: 1089–1099.
  • 17. Timur S, Pazarlıoğlu N, Pilloton R, Telefoncu A. 2004. Thick film sensors based on laccases from different sources immobilized in polyaniline matrix. Sensors Actuators B Chemical; 97: 132–136.
  • 18. Escutia IP, Gomez JJ, Calas-Blanchard C, Marty JL, RamirezSilva M.T. 2010. Amperometric biosensor based on a high resolution photopolymer deposited onto a screen-printed electrode for phenolic compounds monitoring in tea infusions. Talanta; 81:1636–1642.
  • 19. Montereali MR, Della Seta L, Vastarella W, Pilloton R. 2010. A disposable Laccase– Tyrosinase based biosensor for amperometric detection of phenolic compounds in must and wine. Journal of Molecular Catalysis B Enzymatic; 64: 189– 194.
  • 20. Li D, Luo L, Pang Z, Ding L, Wang Q, Ke H, et al. 2014. Novel phenolic biosensor based on a magnetic polydopaminelaccase-nickel nanoparticle loaded carbon nano fiber composite. ACS Applied Materials Interfaces; 6: (7) 5144– 5151.
  • 21. Oliveira TMBF, Fatima Barroso M, Morais S, de Lima-Neto P, Correia AN, Oliveira MBPP, et al. 2013. Biosensor based on multi-walled carbon nanotubes paste electrode modified with laccase for pirimicarb pesticide quantification. Talanta; 106: 137–143.
  • 22. Rahman A, Noh H, Shim Y. 2008. Direct electrochemistry of laccase immobilized on Au nanoparticles encapsulateddendrimer bonded conducting polymer: application for a catechin sensor. Analytical Chemistry; 80: 8020–8027.
  • 23. Rawal R, Chawla, Devender S, Pundir C.S. 2012. An amperometric biosensor based on laccase immobilized onto Fe3O4NPs/cMWCNT/PANI/Au electrode for determination of phenolic content in tea leaves extract. Enzyme and Microbial Technology; 51: 179–185.
  • 24. Vianello F, Cambria A, Ragusa S, Cambria MT, Zennaro L, Rigo A. 2004. A high sensitivity amperometric biosensor using a monomolecular layer of laccase as biorecognition element. Biosensors and Bioelectronics; 20: 315–321.
  • 25. Wan J, Si Y, Li C, Zhang K. 2016. Bisphenol A electrochemical sensor based on multiwalled carbon nanotubes/polythiophene/Pt nanocomposites modified electrode. Analytical Methods; 8: 3333-3338.
  • 26. Ölçer, Z, Esen, E, Muhammad, T, Ersoy, A, Budak, S, Uludag, Y. 2014. Fast and sensitive detection of mycotoxins in wheat using microfluidics based Real-timeElectrochemical Profiling. Biosensensors and Bioelectronics; 62:163–169.
  • 27. Ölcer, Z, Esen, E, Ersoy, A, Budak, S, Kaya, DS, Gök, MY, Barut, S, Üstek, D, Uludag, Y. 2015. Microfluidics and nanoparticles based amperometric biosensor for the detection of cyanobacteria (Planktothrix agardhii NIVA-CYA 116) DNA. Biosensors and Bioelectronics; 70: 426-432.
  • 28. Uludag, Y, Olcer, Z, Sagiroglu, MS. 2014. Design and characterisation of thin-film electrode array with shared reference/counter electrodes for electrochemical detection. Biosensors and Bioelectronics; 57: 85-90.
  • 29. Chidsey, CED, Loiacono, DN. 1990. Chemical Functionality in Self -Assembled Monolayers: Structural and Electrochemical Properties. Langmuir; 6: 682-691.
  • 30. Basmaz, G, Öztürk, N. 2017. Determination of Curcumin in Turmeric Sample Using Edge Plane Pyrolytic Graphite Electrode. Celal Bayar University Journal of Science; 13:3, 689-694.
  • 31. Koçak, ÇC. 2019. Vanillin Determination in Food Products with Pd Nanoparticles Modified Poly(Methylene Blue) Film Electrode. Celal Bayar University Journal of Science; 15:2, 211-215.
  • 32. Bange, A, Halsall, HB, Heineman, WR. 2005. Microfluidic immunosensor systems. Review, Biosensors & Bioelectronics; 20: 2488-2503.
  • 33. Habermüller, K, Mosbach, M, Schuhmann, W. 2000. Electrontransfer mechanisms in amperometric biosensors Review. Fresenius Journal of Analytical Chemistry; 366: 560-568.