Design and Implementation of a Cost Effective Quartz Crystal Microbalance System for Monitoring Small Changes on any Surface

Design and Implementation of a Cost Effective Quartz Crystal Microbalance System for Monitoring Small Changes on any Surface

Quartz crystal microbalance systems are widely used in different fields from biology to electronic. Those devices are very sensitive to mass changes on the piezoelectric crystal surface in nano gram scale and therefore can be used to detect even a single virus on surface of any substance. Although they are very practical and versatile, they are sold with very high prices and thus hindering the usage for someone with tight research budget. In this work, we try to find a cost effective solution and bring this device into the price range on two to three orders of magnitude lower than the commercial counterparts. For that purpose, we develop a cost effective quartz crystal microbalance system using a cost effective microcontroller and a typical oscillator circuit and the final product can be used in different fields to detect the mass change on any surface caused by different reactions or effects.

___

  • A. Alassi, M. Benammar, D. Brett, "Quartz crystal microbalance electronic interfacing systems: A review." Sensors, Vol.17, 12, (2017), pp. 2799.
  • K.N. Chappanda, O. Shekhah, O. Yassine, S.P. Patole, M. Eddaoudi, K.N. Salama, "The quest for highly sensitive QCM humidity sensors: The coating of CNT/MOF composite sensing films as case study" Sensors and Actuators B: Chemical, Vol.257, (2018), pp.609-619.
  • X. Cha, F. Yu, Y. Fan, J. Chen, L. Wang, Q. Xiang, J. Xu, "Superhydrophilic ZnO nanoneedle array: Controllable in situ growth on QCM transducer and enhanced humidity sensing properties and mechanism" Sensors and Actuators B: Chemical, Vol.263, (2018), pp.436-444.
  • A. Erol, S. Okur, N. Yağmurcukardeş, M.Ç. Arıkan, "Humidity-sensing properties of a ZnO nanowire film as measured with a QCM" Sensors and Actuators B: Chemical, Vol.152, (2011), pp.115-120.
  • F. Pascal-Delannoy, B. Sorli, A. Boyer, "Quartz crystal microbalance (QCM) used as humidity sensor" Sensors and Actuators A: Physical, Vol.84, (2000), pp.285-291.
  • B. Ding, J. Kim, Y. Miyazaki, S. Shiratori, "Electrospun nanofibrous membranes coated quartz crystal microbalance as gas sensor for NH3 detection" Sensors and Actuators B: Chemical, Vol.101, 3, (2004), pp.373-380.
  • I. A. Koshets, Z. I. Kazantseva, Y. M. Shirshov, S. A. Cherenok, V. I. Kalchenko, "Calixarene films as sensitive coatings for QCM-based gas sensors" Sensors and Actuators B: Chemical, Vol.106, 1, (2005), pp.177-181.
  • M. M. Kamel, M. K. El Nimr, S. T. Assar, A. S. Atlam, "Design of a Simple Low-Cost Quartz Crystal Microbalance System" Instrumentation Science & Technology, Vol.41, 5, (2013), pp.473-489.
  • E. S. Muckley, C. Anazagasty, C. B. Jacobs, T. Hianik, I. N. Ivanov, "Low-cost scalable quartz crystal microbalance array for environmental sensing" In Organic Sensors and Bioelectronics IX International Society for Optics and Photonics, Vol.9944, (2016), pp.99440Y.
  • G. Sauerbrey, "The use of quartz crystal oscillators for weighing thin layers and for microweighing applications" Zeitschrift für Physik, Vol.155, 3, (1959), pp.206–222.
  • Turkdogan, S. J Mater Sci: Mater Electron (2019). https://doi.org/10.1007/s10854-019-01384-z
  • "Crystal Oscillator." TOYOCOM. Accessed February 21, 2019. http://eshop-bg.com/PDFs/CrystalOscillators/TOYOCOM_TCO-711A.pdf
  • "FreqCount Library." PJRC. Accessed February 21, 2019. https://www.pjrc.com/teensy/ td_libs_FreqCount.html.