Comparison of the methods of intracorporeal knot and hem-o-lok clip to cover the stumps in laparoscopic appendectomy

Comparison of the methods of intracorporeal knot and hem-o-lok clip to cover the stumps in laparoscopic appendectomy

Aim: Laparoscopic appendectomy (LA) is used in acute appendicitis treatment in many centers today. Various methods such as intracorporeal knot, endoloop, stapler and hem-o-lok clip are used to close of the appendix stump during LA. All of these methods has several advantages and disadvantages. In this study, we aimed to compare the effect of the intracorporal knot method with hem-o-lok clip method to close of the appendix stump in LA.Material and Methods: Operative data, complications and follow-up results of 143 patients which treated with LA between January 2012 and December 2017 were evaluated retrospectively.Results: Sixty-four patients (44.7%) were males and 79 (55.2%) were females. Seventy-five patients (52.4%) were treated with 2/0 polyglactin (coated vicyrl, ethicon) sutures and 68 patients (47%) were treated with hem-o-lok clip XL (weck hem-o-lok polymer ligation system) for intracorporeal knot to close of the appendix stump. Patients were compared according to the duration of operation, the duration of hospitalization and postoperative complications and there were no statistically significant difference between the data of the cases according to the groups (p = 0.197, p = 0.902, p = 0.503, respectively).Conclusion: We identified that both techniques for appendix stump closure are effective and safe methods in LA.

___

  • Saia M, Buja A, Baldovin T, et al. Trend, variability, and outcome of open vs. laparoscopic appendectomy based on a large administrative data base. Surg Endosc 2012;26:2353-9.
  • C. McBurney, “The incision made in the abdominal wall in cases of appendicitis, with a description of a newmethod of operating,” Ann Surg 1984;20:38-43.
  • Masoomi H, Mills S, Dolich MO, et al. Does Laparoscopic Appendectomy Impartan Advantage over Open Appendectomy in Elderly Patients? World J Surg 2012;36:1534-9.
  • Delibegović S. The use of a single Hem-o-lok clip in securing the base of the appendix during laparoscopic appendectomy. J Laparoendosc Adv Surg Tech A 2012;22:85-7.
  • Sohn M, Hoffmann M, Pohlen U, et al. Stump closure in laparoscopic appendectomy. Influence of endoloop or linear stapler on patient outcome. Chirurg 2014;85:46-50.
  • Ekeh AP, Wozniak CJ, Monson B, Laparoscopy in the contemporary management of acute appendicitis. Am J Surg 2007;193:310-3.
  • Jadallah FA, Abdul-Ghani AA, Tibblin S. Diagnostic laparoscopy reduces unnecessary appendicectomy in fertile woman. Eur J Surg 1994;160:41-5.
  • Munakata K, Uemura M, Shimizu J, et al. Gasless transumbilical laparoscopic-assisted appendectomy as a safe and cost-effective alternative surgical procedure for mild acute appendicitis. Surg Today 2016;46:319-25.
  • Tümay LV, Güner OS, Zorluoğlu A. Laparoscopic appendectomy experience 132 cases. Kolon Rektum Hast Derg 2010;20:115-20.
  • Gomes CA, Junior CS, de Peixoto RO, et al. Appendiceal stump closure by metal endoclip in the management of complicated acute appendicitis. World J Emerg Surg 2013;8:35.
  • Ates M, Dirican A, Ince V, et al. Comparison of intracorporeal knot-tying suture (polyglactin) and titanium endoclips in laparoscopic appendiceal stump closure: a prospective randomized study. Surg Laparosc Endosc Percutan Tech 2012;22:226-31.
  • Arcovedo R, Barrera H, Reyes HS. Securing the appendiceal stump with the Gea extracorporeal sliding knot during laparoscopic appendectomy is safe and economical. Surg Endosc 2007;21:1764-7.
  • Kiudelis M, Ignatavicius P, Zviniene K, et al. Analysis of intracorporeal knotting with invaginating suture versus endoloops in appendiceal stump closure. Wideochir Inne Tech Malo Inwazyjne 2013;8:69-73.
  • Cristalli BG, Izard V, Jacob D, et al. Laparoscopic appendectomy using a clip applier. Surg Endosc 1991;5:176-8.
  • Jenwitheesuk K, Chotikawanich E, Saeseow OT, et al. Laparoscopic appendectomy: results of a new technique for stump management. J Med Assoc Thai 2012;95:S7-10.
  • Rickert A, Bönninghoff R, Post S, et al. Appendix stump closure with titanium clips in laparoscopic appendectomy. Langenbecks Arch Surg 2012;397:327-31.
  • Hue CS, Kim JS, Kim K, Het al. The usefulness and safety of hemolok clips for the closure of appendicular stump during laparoscopic appendectomy. J Korean Surg Soc 2013;84:27-32.
  • Delibegovic S, Iljazovic E, Katica M, et al. Tissue reaction to absorbable endoloop, nonabsorbable titanium staples, and polymer Hem-o-lok clip after laparoscopic appendectomy JSLS 2011;15:70-6.
  • Gomes CA, Junior CS, de Peixoto RO, et al. Appendiceal stump closure by metal endoclip in the management of complicated acute appendicitis. World J Emerg Surg 2013;8:35.
  • Costa-Navarro D, Jiménez-Fuertes M, Illán-Riquelme A. Laparoscopic appendectomy: quality care and cost-effectiveness for today’s economy. World J Emerg Surg 2013;8:45.
  • Partecke LI, Kessler W, von Bernstorff W, et al. Laparoscopic appendectomy using a single polymeric clip to close the appendicular stump. Langenbecks Arch Surg 2010;395:1077-82.
  • Delibegovic S, Matovic E. Hem-o-lok plastic clips in securing of the base of the appendix during laparoscopic appendectomy. Surg Endosc 2009;23:2851-4.
Annals of Medical Research-Cover
  • Yayın Aralığı: 12
  • Yayıncı: İnönü Üniversitesi Tıp Fakültesi
Sayıdaki Diğer Makaleler

Investigation of in vitro amoebicidal activities of Ornithogalum sigmoideum on Acanthamoeba castellanii cysts and trophozoites

Ulku KARAMAN, Zeynep KOLOREN, Bulent KAYNAK

Comparison of different grafting techniques in open wedge high tibial osteotomy in terms of bone healing and functional outcomes

Aydın ARSLAN

The investigation of effects of proton pump inhibitors (PPI) using on maxillary bone mineral density

Yusuf ATALAY, Ahmet Huseyin ACAR, Fatih ASUTAY

Undetectable pancreatic insulinoma during surgery

Cemalettin KOC, Emrah OTAN, Cuneyt KAYAALP, Volkan INCE, Cemalettin AYDIN

Nevirapine mitigates monosodium glutamate induced neurotoxicity and oxidative stress changes in prepubertal mice

Adejoke Yetunde ONAOLAPO, Olakunle James ONAOLAPO

Atypical leiomyoma of the falciforme ligament of the live

Vahide BAZ, Göksel TUZCU, Nidal İFLAZOĞLU

Somatosensory evoked potentials in patients with obstructive sleep apnea syndrome and cerebral hypoxia

Halil AY, Zafer HASAN ALİ SAK

Single center experience in perianal fistula surgery

Osman BARDAKÇI, Ali UZUNKOY, Abdullah ÖZGÖNÜL, Fırat ERKMEN, Hüseyin Cahit YALÇIN, Emre KARACA, Reşit ÇİFTÇİ, Mehmet GÜMER, Orhan GOZENELİ, Mehmet YİLMAZ, Faik TATLİ

Comparison of percutaneous pinning with Kirschner wires and internal fixation with anatomical proximal humeral plates for proximal humeral fractures

Mehmet Akif ALTAY, Celal BOZKURT, Serkan SİPAHİOGLU, Murat ERGÜN, Baran SARİKAYA, Ugur Erdem ISİKAN

Surgery of Zenker’s diverticulum; Single center exper

SUKRU COLAK, Ekrem CAKAR, Bünyamin GÜRBULAK, Hasan BEKTAŞ