Factors associated with needle breakage of antegrade suture passer and effect of intratendinous remnant needle tip on clinical outcomes after arthroscopic rotator cuff repair

Objective: The aim of this study was to evaluate factors associated with the needle breakage of antegrade suture passer and the effect of intratendinous remnant needle tip on clinical outcomes after rotator cuff repair. Methods: We retrospectively reviewed 283 patients (138 men and 145 women; mean age: 59.7 ± 9.3 years) who underwent arthroscopic repair for full-thickness rotator cuff tear. We evaluated the characteristics of 16 patients in whose needle tip had been broken and embedded and remained in the rotator cuff (remnant needle group) and compared them with the remaining 267 patients (control group). Afterwards, another 64 patients were selected from control group (1:4 matching) after propensity score matching (PSM). The groups were compared anatomically with MRI or ultrasonography and functionally (serial pain VAS and ROM; ASES, Constant, UCLA and SST scores) at a minimum follow-up of 1 year. Results: The remnant needle group showed preoperative thicker tendon (6.72 mm vs 5.33 mm, p ¼ 0.047), higher tendinosis (mean grade, 1.88 vs. 1.43, p ¼ 0.029), and more frequent delaminated tears (p ¼ 0.035) compared with control group. When we compare the clinical outcomes after PSM, the initial pain VAS of the remnant needle tip group was higher up to 3 months (pain VAS: 4.13 ± 2.07 vs 2.48 ± 1.61 (p ¼ 0.032) at 5 weeks and 3.79 ± 2.12 vs 2.25 ± 1.76 (p ¼ 0.044) at 3 months), however the difference disappeared after 6 months postoperatively. In final evaluation, there was no significant differences in every outcome parameters (all p > 0.05). Conclusion: Breakage of the needle of the antegrade suture passer occurred more frequently in the thicker tendon, higher tendinosis, and delaminated tears. The retained broken needle tip was associated with higher pain scores during the early postoperative period, but revealed no difference in final outcomes by using PSM.

___

Galatz LM, Ball CM, Teefey SA, Middleton WD, Yamaguchi K. The outcome and repair integrity of completely arthroscopically repaired large and massive rotator cuff tears. J Bone Joint Surg Am. 2004;86-A(2):219e224.

Gerber C, Fuchs B, Hodler J. The results of repair of massive tears of the rotator cuff. J Bone Joint Surg Am. 2000;82(4):505e515.

Fehringer EV, Sun J, VanOeveren LS, Keller BK, Matsen 3rd FA. Full-thickness rotator cuff tear prevalence and correlation with function and comorbidities in patients sixty-five years and older. J Shoulder Elbow Surg. 2008;17(6):881e885.

Hapa O, Karakas¸ lı A, Bas¸ çı O, Cici H, Çeçen B, Havitçioglu H. The primary factor for suture configuration at rotator cuff repair: width of mattress or distance from tear edge. Acta Orthop Traumatol Turc. 2016 Aug;50(4):448e451.

Gotman I, Ben-David D, Unger RE, Bose T, Gutmanas EY, Kirkpatrick CJ. Mesenchymal stem cell proliferation and differentiation on load-bearing trabecular Nitinol scaffolds. Acta Biomater. 2013;9(9):8440e8448.

Song HS, Ramsey ML. Suture passing needle breakage during arthroscopic rotator cuff repair: a complication report. Arthroscopy. 2008;24(12):1430e1432.

Oh JH, Kim SH, Lee HK, Jo KH, Bin SW, Gong HS. Moderate preoperative shoulder stiffness does not alter the clinical outcome of rotator cuff repair with arthroscopic release and manipulation. Arthroscopy. 2008;24(9):983e991.

Chung SW, Huong CB, Kim SH, Oh JH. Shoulder stiffness after rotator cuff repair: risk factors and influence on outcome. Arthroscopy. 2013;29(2): 290e300.

Chung SW, Park JS, Kim SH, Shin SH, Oh JH. Quality of life after arthroscopic rotator cuff repair: evaluation using SF-36 and an analysis of affecting clinical factors. Am J Sports Med. 2012;40(3):631e639.

DeOrio JK, Cofield RH. Results of a second attempt at surgical repair of a failed initial rotator-cuff repair. J Bone Joint Surg Am. 1984;66(4):563e567.

Goutallier D, Postel JM, Bernageau J, Lavau L, Voisin MC. Fatty muscle degeneration in cuff ruptures. Pre- and postoperative evaluation by CT scan. Clin Orthop Relat Res. 1994;304:78e83.

Fuchs B, Weishaupt D, Zanetti M, Hodler J, Gerber C. Fatty degeneration of the muscles of the rotator cuff: assessment by computed tomography versus magnetic resonance imaging. J Shoulder Elbow Surg. 1999;8(6):599e605.

Walz DM, Miller TT, Chen S, Hofman J. MR imaging of delamination tears of the rotator cuff tendons. Skeletal Radiol. 2007;36(5):411e416.

Gilbert F, Meffert RH, Schmalzl J, Weng AM, Kostler H, Eden L. Grade of € retraction and tendon thickness correlates with MR-spectroscopically measured amount of fatty degeneration in full thickness supraspinatus tears. BMC Musculoskelet Disord. 2018;21(1):19e197.

Sein ML, Walton J, Linklater J, et al. Reliability of MRI assessment of supraspinatus tendinopathy. Br J Sports Med. 2007;41(8):e1ee4.

Chung SW, Kim JY, Yoon JP, Lyu SH, Rhee SM, Oh SB. Arthroscopic repair of partial-thickness and small full-thickness rotator cuff tears: tendon quality as a prognostic factor for repair integrity. Am J Sports Med. 2015;43(3): 588e596.

Liem YS, Wong JB, Hunink MM, de Charro FT, Winkelmayer WC. Propensity scores in the presence of effect modification: a case study using the comparison of mortality on hemodialysis versus peritoneal dialysis. Emerg Themes Epidemiol. 2010;7(1):1.

Sugaya H, Maeda K, Matsuki K, Moriishi J. Repair integrity and functional outcome after arthroscopic double-row rotator cuff repair. A prospective outcome study. J Bone Joint Surg Am. 2007;89(5):953e960.

Nirschl RP. Elbow tendinosis/tennis elbow. Clin Sports Med. 1992;11(4): 851e870.

Kim MS, Kim DW, Choi YE, Bachman Jr L, Kim SH. Performance of antegrade suture passers according to tendon thickness. Int J Shoulder Surg. 2015;9(2): 47e51.

Sonnabend DH, Yu Y, Howlett CR, Harper GD, Walsh WR. Laminated tears of the human rotator cuff: a histologic and immunochemical study. J Shoulder Elbow Surg. 2001;10(2):109e115.

Sebecic B, Japjec M, Dojcinovic B, Zgaljardic I, Staresinic M. Aggressive granulomatosis after cementless total hip arthroplasty as a result of inflammatory reaction to metal debris: case report. Acta Clin Croat. 2013;52(4):492e496.

Hasegawa M, Yoshida K, Wakabayashi H, Sudo A. Prevalence of adverse reactions to metal debris following metal-on-metal THA. Orthopedics. 2013;36(5):e606ee612.

Surov A, Thermann F, Behrmann C, Spielmann RP, Kornhuber M. Late sequelae of retained foreign bodies after world war II missile injuries. Injury. 2012;43(9): 1614e1616.

Falagas ME, Kasiakou SK. Mesh-related infections after hernia repair surgery. Clin Microbiol Infect. 2005;11(1):3e8.

Ellis A, Bennett DL. Neuroinflammation and the generation of neuropathic pain. Br J Anaesth. 2013;111(1):26e37.

Rabe AJ, Shiels WE. Ultrasound guided removal of an intratendinous foreign body in an adolescent. J Am Osteopath Coll Radiol. 2012;1(3):27e29.

Szpaderska AM, DiPietro LA. Inflammation in surgical wound healing: friend or foe? Surgery. 2005;137(5):571e573.

Zheng F, Lin Y, Verbeken E, et al. Host response after reconstruction of abdominal wall defects with porcine dermal collagen in a rat model. Am J Obstet Gynecol. 2004;191(6):1961e1970.

Rodeo SA, Arnoczky SP, Torzilli PA, Hidaka C, Warren RF. Tendon-healing in a bone tunnel. A biomechanical and histological study in the dog. J Bone Joint Surg Am. 1993;75(12):1795e1803.
Acta Orthopaedica et Traumatologica Turcica-Cover
  • ISSN: 1017-995X
  • Başlangıç: 2015
  • Yayıncı: Türk Ortopedi ve Travmatoloji Derneği
Sayıdaki Diğer Makaleler

Umbrella handle technique for fixation of FDP avulsion fracture

Murat KAYALAR, Bekir KARAKILIÇ, Tahir Sadık SÜGÜN

Excision and short segment fusion of a double ipsilateral lumbar hemivertebrae associated with a diastematomyelia and fixed pelvic obliquity

ALPASLAN ŞENKÖYLÜ, Mehmet ÇETİNKAYA, Erdem AKTAŞ, Engin ÇETİN

Outcomes of isokinetic tests and functional assessment of anterior cruciate ligament reconstruction: Transtibial versus single anatomic femoral tunnel technique

Koray BAŞDELİOĞLU, GÖKHAN MERİÇ, Zekine PÜNDÜK, Devrim AKSEKİ, AZİZ ATİK, SERDAR SARGIN

Association of quadriceps angle with plantar pressure distribution, navicular height and calcaneo-tibial angle

ATA ELVAN, İBRAHİM ENGİN ŞİMŞEK, MEHMET ALPHAN ÇAKIROĞLU, Salih ANGIN

Novel multilayer meniscal scaffold provides biomechanical and histological results comparable to polyurethane scaffolds: An 8 week rabbit study

NİHAT DEMİRHAN DEMİRKIRAN, HASAN HAVITÇIOĞLU, AYLİN ZİYLAN, ÜLKER CANKURT, Reşi̇t Buğra HÜSEMOĞLU

Intravascular papillary endothelial hyperplasia along the intrinsic muscle after hand contusion injury: Report of two cases

Chi-Yu WANG, Chung-Chih HONG, Zheng-Yi HUANG, Chih-Hsin WANG

Evaluation of grip strength in hook of hamate fractures treated with osteosynthesis. Is this surgical treatment necessary?

Claudia LAMAS-GOMEZ, Laura VELASCO-GONZALEZ, Aranzazu GONZALEZ-OSUNA, Marta ALMENARA-FERNANDEZ, Luis TRİGO-LAHOZ, Xavier AGUILERA-ROIG

Tranexamic acid is effective in lower doses with infusion in total knee arthroplasty

Hande Gürbüz AYTULUK, Hasan Onur YAKA

Epidermal growth factor enhances spinal fusion: Posterolateral lumbar fusion model on rats

Engin ÇETİN, İsmail DALDAL, Ali EREN, SAADET ÖZEN AKARCA DİZAKAR, SUNA ÖMEROĞLU, MUHAMMET BORA UZUNER, HAKAN HAMDİ ÇELİK, Hasan Hüseyin SAYGILI, BENAT KOÇKAR, ALPASLAN ŞENKÖYLÜ

Correction of distal femoral valgus deformities with fixator-assisted plating: How accurate is the correction?

Güney YILMAZ, Sancar BAKIRCIOĞLU