Evaluation of children presenting to the emergency room after electrical injury
Background/aim: To evaluate children who presented to the Pediatric Emergency Department with electrical injury and to discuss the follow-up of these cases and potential precautions that can be taken. Materials and methods: A total of 36 patients presented to the Pediatric Emergency Department with electrical injury between May 2010 and May 2013, and these cases were investigated retrospectively. The patients? age and sex, location and form of exposure to electric current, seasonal distribution, length of hospital stay, musculoskeletal and cardiovascular system complications, renal damage, and treatments were recorded. Results: The majority of the patients were exposed to low-voltage electrical current at home. When the patients were evaluated based on the type of electric current, alanine transaminase, aspartate transaminase, creatine kinase, and creatine kinase-myocardial isoenzyme levels were found to be significantly higher among patients who were exposed to high-voltage electric current. None of the patients died, and the mean length of hospital stay was 2.50 ± 1.06 days. Conclusion: Electrical injuries can present with a wide variety of problems, ranging from a simple injury to life-threatening severe multiple organ injury. Even simple precautions can prevent possible morbidity and mortality. We think that the public level of knowledge and awareness should be increased.
Evaluation of children presenting to the emergency room after electrical injury
Background/aim: To evaluate children who presented to the Pediatric Emergency Department with electrical injury and to discuss the follow-up of these cases and potential precautions that can be taken. Materials and methods: A total of 36 patients presented to the Pediatric Emergency Department with electrical injury between May 2010 and May 2013, and these cases were investigated retrospectively. The patients? age and sex, location and form of exposure to electric current, seasonal distribution, length of hospital stay, musculoskeletal and cardiovascular system complications, renal damage, and treatments were recorded. Results: The majority of the patients were exposed to low-voltage electrical current at home. When the patients were evaluated based on the type of electric current, alanine transaminase, aspartate transaminase, creatine kinase, and creatine kinase-myocardial isoenzyme levels were found to be significantly higher among patients who were exposed to high-voltage electric current. None of the patients died, and the mean length of hospital stay was 2.50 ± 1.06 days. Conclusion: Electrical injuries can present with a wide variety of problems, ranging from a simple injury to life-threatening severe multiple organ injury. Even simple precautions can prevent possible morbidity and mortality. We think that the public level of knowledge and awareness should be increased.
___
- Cander B, Dur A, Koyuncu F, Gül M, Girişgin S. The demographical characteristic and affecting factors on length of stay in hospital due to electrical injuries. Akademik Acil Tıp Dergisi 2010; 2: 72–74 (in Turkish with English abstract).
- Carleton SC. Cardiac problems associated with electrical injury. Cardiol Clin 1995; 13: 263–266.
- Güloğlu C, Orak M, Altuncı YA. Electric injury and burns. Turkiye Klinikleri J Surg Med Sci 2007; 3: 84–88.
- Chilbert M, Maiman D, Sances A Jr, Myklebust J, Prieto TE, Swiontek T, Heckman M, Pintar K. Measure of tissue resistivity in experimental electrical burns. J Trauma 1985; 25: 209–215.
- Koumbourlis AC. Electrical injuries. Crit Care Med 2002; 30 (11 Suppl.): S424–S430.
- Smith MA, Muehlberger T, Dellon AL. Peripheral nerve compression associated with low-voltage electrical injury without associated significant cutaneous burn. Plast Reconstr Surg 2002; 109: 137–144.
- Rai J, Jeschke MG, Barrow RE, Herndon DN. Electrical injuries: a 30-year review. J Trauma 1999; 46: 933–936.
- Arnoldo BD, Purdue GF, Kowalske, Helm PA, Burris A, Hunt JL. Electrical injuries: a 20-year review. J Burn Care Rehabil 2004; 25: 479–484.
- Rabban JT, Blair AJ, Rosen CL. Mechanism of pediatric electrical injury. New implications for product safety and injury prevention. Arch Pediatr Adolesc Med 1997; 151: 696– 700.
- Zubair M, Besner GE. Pediatric electrical burns: management strategies. Burns 1997; 23: 413–420.
- Celik A, Ergün O, Ozok G. Pediatric electrical injuries: a review of 38 consecutive patients. J Pediatr Surg 2004; 39: 1233–1237.
- Varol E, Ozaydin M, Altinbas A, Dogan A. Low-tension electrical injury as a cause of atrial fibrillation: a case report. Tex Heart Inst J 2004; 31: 186–187.
- Claudet I, Maréchal C, Debuisson C, Salanne S. Risk of arrhythmia and domestic low-voltage electrical injury. Arch Pediatr 2010; 17: 343–349 (in French with English abstract).
- Kang X, Sun B, Sun S, Hou W, Xie F, Rong M, Sun R. Determination enzyme protein of CK-MB m-AST and ChE by immunological methods and survey of its applying values. Rinsho Byori 1998; 46: 713–717 (in Japanese with English abstract).
- Kopp J, Loos B, Spilker G, Horch RE. Correlation between serum creatinine kinase levels and extent of muscle damage in electrical burns. Burns 2004; 30: 680–683.