Development of Gold Porous Plate Electrode and Examination of Its Performance for Iodine Determination

A novel procedure for the construction of a home-made gold porous plate electrode is described. A plate of silver and gold alloy was treated with nitric acid or alternatively by anodic oxidation to remove the silver component, leaving a porous surface having active sites for adsorption. The performance of the electrode developed was tested using iodine solution as analyte material. The parameters related to the working conditions were optimized before the examination of analytical characteristics. Under the optimal conditions, the voltammetric results show that the gold porous plate electrode offers the detection limit of 2.18 x 10-5 M and reproducibility of 7.8% (n = 4). The electrode performance was compared with that of glassy carbon electrode (G.C.E), gold-wire and platinized Pt electrodes in terms of current density for 2 x 10-4 M iodine solution. In conclusion, it is observed that the gold porous plate electrode has better current density than gold wire and platinized Pt electrodes.

Development of Gold Porous Plate Electrode and Examination of Its Performance for Iodine Determination

A novel procedure for the construction of a home-made gold porous plate electrode is described. A plate of silver and gold alloy was treated with nitric acid or alternatively by anodic oxidation to remove the silver component, leaving a porous surface having active sites for adsorption. The performance of the electrode developed was tested using iodine solution as analyte material. The parameters related to the working conditions were optimized before the examination of analytical characteristics. Under the optimal conditions, the voltammetric results show that the gold porous plate electrode offers the detection limit of 2.18 x 10-5 M and reproducibility of 7.8% (n = 4). The electrode performance was compared with that of glassy carbon electrode (G.C.E), gold-wire and platinized Pt electrodes in terms of current density for 2 x 10-4 M iodine solution. In conclusion, it is observed that the gold porous plate electrode has better current density than gold wire and platinized Pt electrodes.
Turkish Journal of Chemistry-Cover
  • ISSN: 1300-0527
  • Yayın Aralığı: Yılda 6 Sayı
  • Yayıncı: TÜBİTAK
Sayıdaki Diğer Makaleler

Excellent and convenient procedures for reduction of benzene and its derivaties

Aliye ALTUNDAŞ, Melek KARAKAYA, Abdullah MENZEK, Demirci Demet GÜLTEKİN

Excellent and Convenient Procedures for Reduction of Benzene and Its Derivatives

Aliye ALTUNDAŞ, Abdullah MENZEK*, Demet DEMİRCİ GÜLTEKİN And

Voltammetric, UV Absorption and Viscometric Studies of the Interaction of Norepinephrine with DNA

Mehmet ASLANOĞLU, Necla ÖGE

Analysis of the Essential Oil Composition of Sideritis albiflora Using Direct Thermal Desorption and Headspace GC-MS Techniques

Gülaçtı TOPÇU, Aslı BARLA, Ahmet C. GÖREN

Triterpene Saponins from Nigella sativa L.

Mustafa Kemal TAŞKIN, Özgen Alankuş ÇALIŞKAN, Hüseyin ANIL, Hassan ABOU-GAZAR, Ikhlas A. KHAN, Erdal BEDİR

A new approach to the ring opening reactions of 2,7,7-trimethyl-3,3-dibromotricyclo[4.1.1.$0^{2,4}$] octane

Ömer ZAİM, Zekir ŞENOL, Metin BALCI

Organotin(IV) Derivatives of N-Maleoylamino Acids: Their Synthesis and Structural Elucidation

Moazzam H. BHATTI, Saqib ALI, Farhat HUMA

Selective oxidation of thiols to disulfides catalyzed by iron (III)-tetra phenyl porphrin using urea-hydrogen peroxide as oxidizing reagent

Majid MOGHADAM, Morteza MONTAZEROZOHORI, Mohammad Hosein HABIBI, Khodabakhsh NIKNAM, Bahador KARAMI

Development of Gold Porous Plate Electrode and Examination of Its Performance for Iodine Determination

Ülkü Anık KIRGÖZ, Hüseyin TURAL

The Electroanalytical Determination of Sodium Borohydride Using a Gold Electrode

Hüseyin ÇELİKKAN, Hasan AYDIN, M. Levent AKSU