Determination of blood glucose parameter from human blood serum by using a quartz crystal microbalance sensor coated with phthalocyanines compounds

Determining the blood glucose level is important for the prevention and treatment of diabetes mellitus. We developed a sensor system using Quartz Crystal Ivlicrobalance (QCM) to determine the blood glucose level from human blood serum. This study consists of two experimental stages: artificial glucose/pure water solution tests and human blood serum tests. In the first stage of the study, the QCM sensor with the highest performance was identified using artificial glucose solution concentrations. In the second stage of the study, human blood serum measurements were performed using QCM to determine blood glucose levels. QCM sensors were coated with phthalocyanines (Pcs) by jet spray method. The blood glucose values of 96 volunteers, which ranged from 71 mg/dL to 329 mg/dL, were recorded. As a result of the study, human glucose values were determined with an average error of 3.25%.

___

  • Al-Sagur H, 2019, BIOSENS BIOELECTRON, V139, DOI 10.1016/j.bios.2019.111323
  • Bergenstal RM, 2013, DIABETES CARE, V36, pE107, DOI 10.2337/dc13-0295
  • Cheng TJ, 2001, ANAL CHIM ACTA, V432, P101, DOI 10.1016/S0003-2670(00)01346-5
  • Erbahar DD, 2014, SENSOR ACTUAT B-CHEM, V190, P651, DOI 10.1016/j.snb.2013.09.034
  • Harbeck M, 2010, SENSOR ACTUAT B-CHEM, V150, P346, DOI 10.1016/j.snb.2010.06.062
  • Harbeck S, 2013, SENSOR ACTUAT B-CHEM, V176, P838, DOI 10.1016/j.snb.2012.08.020
  • Huang HH, 2004, SENSOR ACTUAT B-CHEM, V101, P316, DOI 10.1016/j.snb.2004.04.001
  • Juan CG, 2019, SENSORS-BASEL, V19, DOI 10.3390/s19173779
  • KANAZAWA KK, 1985, ANAL CHEM, V57, P1770, DOI 10.1021/ac00285a062
  • KANAZAWA KK, 1985, ANAL CHIM ACTA, V175, P99
  • Kankare J, 2002, LANGMUIR, V18, P7092, DOI 10.1021/la025911w
  • KING WH, 1964, ANAL CHEM, V36, P1735, DOI 10.1021/ac60215a012
  • KONASH PL, 1980, ANAL CHEM, V52, P1929, DOI 10.1021/ac50062a033
  • Lin TY, 2004, BIOSENS BIOELECTRON, V20, P75, DOI 10.1016/j.bios.2004.01.028
  • MARTIN SJ, 1991, ANAL CHEM, V63, P2272, DOI 10.1021/ac00020a015
  • Muller L, 2010, ANAL CHEM, V82, P658, DOI 10.1021/ac9021117
  • Panda A, 2020, APPL PHYS A-MATER, V126, DOI 10.1007/s00339-020-3328-8
  • Rasooly A, 2005, METHODS, V37, P1, DOI 10.1016/j.ymeth.2005.05.004
  • Saraoglu HM, 2010, IEEE SENS J, V10, P104, DOI 10.1109/JSEN.2009.2035769
  • SAUERBREY G, 1959, Z PHYS, V155, P206, DOI 10.1007/BF01337937
  • Shoji M, 2010, POLYM ADVAN TECHNOL, V21, P646, DOI 10.1002/pat.1480
  • Tarakci DK, 2013, J PORPHYR PHTHALOCYA, V17, P548, DOI 10.1142/S1088424613500399
  • Tasaltin C, 2010, SENSOR ACTUAT B-CHEM, V150, P781, DOI 10.1016/j.snb.2010.07.056
  • Voinova MV, 2002, BIOSENS BIOELECTRON, V17, P835, DOI 10.1016/S0956-5663(02)00050-7
  • Yoshihiro T, 1999, METHOD OPTICAL RECOR, Patent No. JP 11254827 A 19990921
  • Yoshiyama H, 2008, CHEM COMMUN, P1977, DOI 10.1039/b800918j