Objective: This study aimed to evaluate the clinical use and outcomes of the patient-specific root-analogue immediate titanium premolar dental implants (PRIs) that are manufactured by using computer numerical control (CNC) machine. Materials and Methods: Three-dimensional models of the 15 non-restorable premolar teeth were constructed from cone-beam computed tomography datasets and transferred to a specific modelling software to design the PRIs. PRIs were manufactured from titanium by using a CNC machine and placed immediately after tooth extraction. Implants were evaluated clinically and radiologically oneyear after implant placement. Results: Fifteen patients (five males, 10 females), aged between 18-53 years (average 29.9) were included in the study. The success rate was 80% after oneyear follow up. There was no peri-implant radiolucency around survival implants. The 1-year mean marginal bone loss was 1.1 mm (±0.4). Clinically healthy gingival margins were observed without any signs of periodontitis or implant mobility. The mean Periotest® value was -4.7±0.3. Conclusion: Relatively high success rate was observed for upper premolar PRIs (92.3%) compared to lower premolar PRIs (50%). PRI concept is a new promising treatment modality. Further studies with long-term follow-up are necessary.
Amaç: Bu çalışmanın amacı, dental bilgisayarlı sayısal kontrol (CNC) cihazıyla üretilen kişiye özel kök analoğu immediat titanyum premolar dental implantların (KÖİ) klinik kullanımını ve sonuçlarını değerlendirmektir. Gereç ve Yöntemler: On beş adet restore edilemeyen premolar dişin konik ışınlı bilgisayarlı tomografi kesitleri kullanılarak 3 boyutlu modelleri oluşturuldu ve KÖİ tasarımı için özel bir modelleme yazılımına aktarıldı. CNC cihazı kullanılarak titanyumdan KÖİ’ler üretildi ve diş çekiminden hemen sonra yerleştirildi. İmplantlar, yerleştirilmelerinden 1 yıl sonra klinik ve radyolojik olarak değerlendirildi. Bulgular: On sekiz - yirmi üç (ortalama 29,9) yaşları arasında 15 (beş erkek, 10 kadın) hasta çalışmaya dahil edildi. Bir yıllık takip sonrasında sağkalım oranı %80 idi. Sağkalan implantlar etrafında peri-implant radyolusensi yoktu. Bir yıllık ortalama marjinal kemik kaybı 1,1 mm (±0,4) idi. Periodontitis bulgusu ya da implant mobilitesi olmaksızın klinik olarak sağlıklı gingival marjinler gözlendi. Ortalama Periotest® değeri -4,7±0,3 idi. Sonuç: Üst çenedeki implantlarda alt çenedekilere göre daha yüksek sağkalım oranı gözlenmiştir. KÖİ konsepti yeni ve umut vadeden bir tedavi yöntemidir. Daha uzun takip süreli ileri çalışmalara ihtiyaç vardır.
___
Telleman G, Meijer HJ, Raghoebar GM. Long-term evaluation of hollow screw and hollow cylinder dental implants: clinical and radiographic results after 10 years. J Periodontol 2006; 77: 203- 10.
Esposito M, Grusovin MG, Chew YS, Coulthard P, Worthington HV. Interventions for replacing missing teeth: 1- versus 2-stage implant placement. Cochrane Database Syst Rev 2009; CD006698.
Schwartz-Arad D, Chaushu G. The ways and wherefores of immediate placement of implants into fresh extraction sites: a literature review. J Periodontol 1997; 68: 915-23.
Hodosh M, Povar M, Shklar G. The dental polymer implant concept. J Prosthet Dent 1969; 22: 371-80.
Lundgren D, Rylander H, Andersson M, Johansson C, Albrektsson T. Healing-in of root analogue titanium implants placed in extraction sockets. An experimental study in the beagle dog. Clin Oral Implants Res 1992; 3: 136-43.
Kohal RJ, Hürzeler MB, Mota LF, Klaus G, Caffesse RG, Strub JR. Custom-made root analogue titanium implants placed into extraction sockets. An experimental study in monkeys. Clin Oral Implants Res 1997; 8: 386-92.
Kohal R, Klaus G, Strub J. Clinical investigation of a new dental immediate implant system-the Relmplant-system. Dtsch Zahnarztl Z 2002; 57: 495-7.
Mangano FG, Cirotti B, Sammons RL, Mangano C. Custom-made, root-analogue direct laser metal forming implant: a case report. Lasers Med Sci 2012; 27: 1241-5.
Mangano FG, De Franco M, Caprioglio A, Macchi A, Piattelli A, Mangano C. Immediate, non-submerged, root-analogue direct laser metal sintering (DLMS) implants: a 1-year prospective study on 15 patients. Lasers Med Sci 2014; 29: 1321-8.
Figliuzzi M, Mangano F, Mangano C. A novel root analogue dental implant using CT scan and CAD/CAM: selective laser melting technology. Int J Oral Maxillofac Surg 2012; 41: 858-62.
Patankar A, Kshirsagar R, Patankar S, Pawar S. Immediate, Non Submerged Root Analog Zirconia Implant in Single Rooted Tooth Replacement: Case Report with 2 years Follow Up. J Maxillofac Oral Surg 2016; 15: 270-3.
Pirker W, Wiedemann D, Lidauer A, Kocher AA. Immediate, single stage, truly anatomic zirconia implant in lower molar replacement: a case report with 2.5 years follow-up. Int J Oral Maxillofac Surg 2011; 40: 212-6.
Pirker W, Kocher A. Root analog zirconia implants: true anatomical design for molar replacement--a case report. Int J Periodontics Restorative Dent 2011; 31: 663-8.
Pirker W, Kocher A. True anatomical zirconia implants for molar replacement: a case report from an ongoing clinical study with a 2‐year follow‐up. Oral Surgery 2009; 2: 144-8.
Pirker W, Kocher A. Immediate, non-submerged, root-analogue zirconia implants placed into single-rooted extraction sockets: 2-year follow-up of a clinical study. Int J Oral Maxillofac Surg 2009; 38: 1127-32.
Pirker W, Kocher A. Immediate, non-submerged, root-analogue zirconia implant in single tooth replacement. Int J Oral Maxillofac Surg 2008; 37: 293-5.
Moin DA, Hassan B, Wismeijer D. Immediate Nonsubmerged Custom Root Analog Implants: A Prospective Pilot Clinical Study. Int J Oral Maxillofac Implants 2018; 33: e37-44.
Fischer J, Schott A, Märtin S. Surface micro-structuring of zirconia dental implants. Clin Oral Implants Res 2016; 27: 162-6.
Albrektsson T, Zarb GA. Determinants of correct clinical reporting. Int J Prosthodont 1998; 11: 517-21.