Patient-specific Root-analogue Immediate Titanium Premolar Dental Implants: Prospective Evaluation of Fifteen Patients with One-year Follow-up

Objective: This study aimed to evaluate the clinical use and outcomes of the patient-specific root-analogue immediate titanium premolar dental implants (PRIs) that are manufactured by using computer numerical control (CNC) machine. Materials and Methods: Three-dimensional models of the 15 non-restorable premolar teeth were constructed from cone-beam computed tomography datasets and transferred to a specific modelling software to design the PRIs. PRIs were manufactured from titanium by using a CNC machine and placed immediately after tooth extraction. Implants were evaluated clinically and radiologically oneyear after implant placement. Results: Fifteen patients (five males, 10 females), aged between 18-53 years (average 29.9) were included in the study. The success rate was 80% after oneyear follow up. There was no peri-implant radiolucency around survival implants. The 1-year mean marginal bone loss was 1.1 mm (±0.4). Clinically healthy gingival margins were observed without any signs of periodontitis or implant mobility. The mean Periotest® value was -4.7±0.3. Conclusion: Relatively high success rate was observed for upper premolar PRIs (92.3%) compared to lower premolar PRIs (50%). PRI concept is a new promising treatment modality. Further studies with long-term follow-up are necessary.

Kişiye Özel Kök Analoğu İmmediat Titanyum Premolar Dental İmplantlar: On beş Hastanın Bir Yıllık Takiplerle İleriye Dönük Değerlendirilmesi

Amaç: Bu çalışmanın amacı, dental bilgisayarlı sayısal kontrol (CNC) cihazıyla üretilen kişiye özel kök analoğu immediat titanyum premolar dental implantların (KÖİ) klinik kullanımını ve sonuçlarını değerlendirmektir. Gereç ve Yöntemler: On beş adet restore edilemeyen premolar dişin konik ışınlı bilgisayarlı tomografi kesitleri kullanılarak 3 boyutlu modelleri oluşturuldu ve KÖİ tasarımı için özel bir modelleme yazılımına aktarıldı. CNC cihazı kullanılarak titanyumdan KÖİ’ler üretildi ve diş çekiminden hemen sonra yerleştirildi. İmplantlar, yerleştirilmelerinden 1 yıl sonra klinik ve radyolojik olarak değerlendirildi. Bulgular: On sekiz - yirmi üç (ortalama 29,9) yaşları arasında 15 (beş erkek, 10 kadın) hasta çalışmaya dahil edildi. Bir yıllık takip sonrasında sağkalım oranı %80 idi. Sağkalan implantlar etrafında peri-implant radyolusensi yoktu. Bir yıllık ortalama marjinal kemik kaybı 1,1 mm (±0,4) idi. Periodontitis bulgusu ya da implant mobilitesi olmaksızın klinik olarak sağlıklı gingival marjinler gözlendi. Ortalama Periotest® değeri -4,7±0,3 idi. Sonuç: Üst çenedeki implantlarda alt çenedekilere göre daha yüksek sağkalım oranı gözlenmiştir. KÖİ konsepti yeni ve umut vadeden bir tedavi yöntemidir. Daha uzun takip süreli ileri çalışmalara ihtiyaç vardır.

___

Telleman G, Meijer HJ, Raghoebar GM. Long-term evaluation of hollow screw and hollow cylinder dental implants: clinical and radiographic results after 10 years. J Periodontol 2006; 77: 203- 10.

Esposito M, Grusovin MG, Chew YS, Coulthard P, Worthington HV. Interventions for replacing missing teeth: 1- versus 2-stage implant placement. Cochrane Database Syst Rev 2009; CD006698.

Schwartz-Arad D, Chaushu G. The ways and wherefores of immediate placement of implants into fresh extraction sites: a literature review. J Periodontol 1997; 68: 915-23.

Hodosh M, Povar M, Shklar G. The dental polymer implant concept. J Prosthet Dent 1969; 22: 371-80.

Lundgren D, Rylander H, Andersson M, Johansson C, Albrektsson T. Healing-in of root analogue titanium implants placed in extraction sockets. An experimental study in the beagle dog. Clin Oral Implants Res 1992; 3: 136-43.

Kohal RJ, Hürzeler MB, Mota LF, Klaus G, Caffesse RG, Strub JR. Custom-made root analogue titanium implants placed into extraction sockets. An experimental study in monkeys. Clin Oral Implants Res 1997; 8: 386-92.

Kohal R, Klaus G, Strub J. Clinical investigation of a new dental immediate implant system-the Relmplant-system. Dtsch Zahnarztl Z 2002; 57: 495-7.

Mangano FG, Cirotti B, Sammons RL, Mangano C. Custom-made, root-analogue direct laser metal forming implant: a case report. Lasers Med Sci 2012; 27: 1241-5.

Mangano FG, De Franco M, Caprioglio A, Macchi A, Piattelli A, Mangano C. Immediate, non-submerged, root-analogue direct laser metal sintering (DLMS) implants: a 1-year prospective study on 15 patients. Lasers Med Sci 2014; 29: 1321-8.

Figliuzzi M, Mangano F, Mangano C. A novel root analogue dental implant using CT scan and CAD/CAM: selective laser melting technology. Int J Oral Maxillofac Surg 2012; 41: 858-62.

Patankar A, Kshirsagar R, Patankar S, Pawar S. Immediate, Non Submerged Root Analog Zirconia Implant in Single Rooted Tooth Replacement: Case Report with 2 years Follow Up. J Maxillofac Oral Surg 2016; 15: 270-3.

Pirker W, Wiedemann D, Lidauer A, Kocher AA. Immediate, single stage, truly anatomic zirconia implant in lower molar replacement: a case report with 2.5 years follow-up. Int J Oral Maxillofac Surg 2011; 40: 212-6.

Pirker W, Kocher A. Root analog zirconia implants: true anatomical design for molar replacement--a case report. Int J Periodontics Restorative Dent 2011; 31: 663-8.

Pirker W, Kocher A. True anatomical zirconia implants for molar replacement: a case report from an ongoing clinical study with a 2‐year follow‐up. Oral Surgery 2009; 2: 144-8.

Pirker W, Kocher A. Immediate, non-submerged, root-analogue zirconia implants placed into single-rooted extraction sockets: 2-year follow-up of a clinical study. Int J Oral Maxillofac Surg 2009; 38: 1127-32.

Pirker W, Kocher A. Immediate, non-submerged, root-analogue zirconia implant in single tooth replacement. Int J Oral Maxillofac Surg 2008; 37: 293-5.

Moin DA, Hassan B, Wismeijer D. Immediate Nonsubmerged Custom Root Analog Implants: A Prospective Pilot Clinical Study. Int J Oral Maxillofac Implants 2018; 33: e37-44.

Fischer J, Schott A, Märtin S. Surface micro-structuring of zirconia dental implants. Clin Oral Implants Res 2016; 27: 162-6.

Albrektsson T, Zarb GA. Determinants of correct clinical reporting. Int J Prosthodont 1998; 11: 517-21.
Meandros Medical And Dental Journal-Cover
  • ISSN: 2149-9063
  • Başlangıç: 2000
  • Yayıncı: Erkan Mor
Sayıdaki Diğer Makaleler

Çocuklarda Oral Prekanseröz Lezyonlar: Pediatrist ve Pedodontistlerin Dikkatine

Şaziye SARI, İlhan KARA, Akif DEMİREL

Oral Precancerous Lesions in Childhood: Attention to the Pediatricians and Pediatric Dentists

ŞAZİYE SARI, İlhan KARA, Akif DEMİREL

Patient-specific Root-analogue Immediate Titanium Premolar Dental Implants: Prospective Evaluation of Fifteen Patients with One-year Follow-up

Ahmet Emin DEMİRBAŞ, Emine Fulya AKKOYUN, Hasan Önder GÜMÜŞ, Banu Arzu ALKAN, Alper ALKAN

Nosokomiyal Enfeksiyonlar ve Sphingomonas Paucimobilis: Olguların Sunumu

Oğuz KARABAY, Aynur ÖZENSOY, Elham BEHZADİ, Fatma SIRMATEL

Çeşitli İrrigasyon Protokollerinin İkili ve Üçlü Antibiyotik Patlarını Uzaklaştırma Etkinliklerinin Değerlendirilmesi

Evren SARIYILMAZ, Cangül KESKİN

Inferior Vena Kavaya Retroperitoneal Tünelli Hemodiyaliz Katateri: Üç Hastalık Olgu

Mehmet KALENDER, Ata ECEVİT, Turan EGE, Okay KARACA, Mehmet TAŞAR

A Rare Cause of Paresthesia: Hypophosphatemia

Zeynep ÖZÖZEN AYAS, Ruhsen ÖNCEL ÖCAL, Ayhan BÖLÜK

Anaphylaxis After the First Dose of Lansoprazole: A Case Report

İskender EKİNCİ, Yusuf KAYAR, Shute Ailia DAE, Ali DUR

Effect of Poly(Methyl Vinyl Ether-comaleicAnhydride) Copolymer on Bond Strength of Experimental Dental Adhesive

Özge ÇELİKSÖZ, ÖZGÜR IRMAK, Zeynep DİKMEN, Batu Can YAMAN, VURAL BÜTÜN, Füsun ÖZER

Relationship Between the Number of Cesarean Deliveries and Maternal-fetal Complications

Özgür Deniz TURAN, Ezgi ÖZDEMİR, Tolga ATAKUL, Emre ZAFER