Intermittency and Inflexibility Blister Pump Impress Factors

Öz Divisional centralized heating and cooling system, cogeneratton system of heat and power and power-gas cogeneration system. In order to further fully and reasonably use the heat in doubleeffect absorption units, double-stage bubble pump must be involved in the adoption o u pump replacing the traditional mechanical solution pump. It was designed a secon generator based on a solar pump-free lithium bromide absorption chiller system. The expenmen adopts the lunate thermosiphon elevation tube, effectively improves the solar energy utility efficiency by decreasing the temperature of heat source. It is established a theoretical model of the bubble pump and took a lot of researches on the impact factors of the bubble pump such as heat input, immersion height and others. Despite there are many thorough reports on single-stage bubble pump, the double-stage bubble pump has been rarely discussed. This study build an experimental apparatus of double-stage bubble pump and use water and different concentrations of lithium bromide solutions as working fluid to study relevant characteristics of double-stage bubble pump. Intermittent operation probably occurs during the running of double-stage bubble pump. Studies of the double-stage bubble pump on its running intermittence and stability and influencing factors will believably provide an important reference in its production and application

Kaynak Göster

Bibtex @ { ejt376600, journal = {European Journal of Technique (EJT)}, issn = {2536-5010}, eissn = {2536-5134}, address = {INESEG Yayıncılık Dicle Üniversitesi Teknokent, Sur/Diyarbakır}, publisher = {Hibetullah KILIÇ}, year = {2011}, volume = {1}, pages = {0 - 0}, doi = {}, title = {Intermittency and Inflexibility Blister Pump Impress Factors}, key = {cite}, author = {Mlakar, Boštjan and Zupančič, Cvetko} }
APA Mlakar, B , Zupančič, C . (2011). Intermittency and Inflexibility Blister Pump Impress Factors . European Journal of Technique (EJT) , 1 (2) , 0-0 . Retrieved from https://dergipark.org.tr/tr/pub/ejt/issue/34022/376600
MLA Mlakar, B , Zupančič, C . "Intermittency and Inflexibility Blister Pump Impress Factors" . European Journal of Technique (EJT) 1 (2011 ): 0-0 <https://dergipark.org.tr/tr/pub/ejt/issue/34022/376600>
Chicago Mlakar, B , Zupančič, C . "Intermittency and Inflexibility Blister Pump Impress Factors". European Journal of Technique (EJT) 1 (2011 ): 0-0
RIS TY - JOUR T1 - Intermittency and Inflexibility Blister Pump Impress Factors AU - Boštjan Mlakar , Cvetko Zupančič Y1 - 2011 PY - 2011 N1 - DO - T2 - European Journal of Technique (EJT) JF - Journal JO - JOR SP - 0 EP - 0 VL - 1 IS - 2 SN - 2536-5010-2536-5134 M3 - UR - Y2 - 2021 ER -
EndNote %0 European Journal of Technique Intermittency and Inflexibility Blister Pump Impress Factors %A Boštjan Mlakar , Cvetko Zupančič %T Intermittency and Inflexibility Blister Pump Impress Factors %D 2011 %J European Journal of Technique (EJT) %P 2536-5010-2536-5134 %V 1 %N 2 %R %U
ISNAD Mlakar, Boštjan , Zupančič, Cvetko . "Intermittency and Inflexibility Blister Pump Impress Factors". European Journal of Technique (EJT) 1 / 2 (Ağustos 2011): 0-0 .
AMA Mlakar B , Zupančič C . Intermittency and Inflexibility Blister Pump Impress Factors. EJT. 2011; 1(2): 0-0.
Vancouver Mlakar B , Zupančič C . Intermittency and Inflexibility Blister Pump Impress Factors. European Journal of Technique (EJT). 2011; 1(2): 0-0.
IEEE B. Mlakar ve C. Zupančič , "Intermittency and Inflexibility Blister Pump Impress Factors", European Journal of Technique (EJT), c. 1, sayı. 2, ss. 0-0, Ağu. 2011