Quantitative comparison of a laterally misplaced pedicle screw with a re-directed screw. How much pull-out strength is lost?

Objective: Redirecting of a laterally misplaced pedicle screw into the accurate position decreases the pull-out strength due to the reinsertion, lateral wall cortical perforation and widening of the pedicle hole. Thus, this biomechanical study was performed to quantitatively analyze the pullout strength of a redirected laterally misplaced pedicle screw into the accurate position. Methods: Thirty pedicules of 15 bovine vertebrae were separated to 3 groups, according to the screw placement method: 1) standard flawless trajectory; 2) trajectory with lateral pedicle wall perforation; 3) trajectory with lateral wall perforation redirected to the standard trajectory. Samples were placed on a universal testing machine and pullout loads were measured. Kruskal-Wallis test was utilized within 95% confidence interval and p value

___

Cotrel Y, Dubousset J, Guillaumat M. New universal instrumentation in spinal surgery. Clin Orthop Relat Res. 1988;227:10e23.

Eggli S, Schlapfer F, Angst M, Witschger P, Aebi M. Biomechanical testing of € three newly developed transpedicular multisegmental fixation systems. Eur Spine J. 1992;1(2):109e116.

Di Silvestre M, Parisini P, Lolli F, Bakaloudis G. Complications of thoracic pedicle screws in scoliosis treatment. Spine (Phila Pa 1976). 2007;32(15):1655e1661.

Nan Li DH, Xing Yonggang, Yanwei LV, Tian Wei. The effect of lateral wall perforation on screw pull-out strength: a cadaveric study. J Orthop Surg Res. 2015;10:6.

Ebraheim NA, Jabaly G, Xu R, Yeasting RA. Anatomic relations of the thoracic pedicle to the adjacent neural structures. Spine (Phila Pa 1976). 1997;22(14): 1553e1556 [Discussion 1557].

Vaccaro AR, Rizzolo SJ, Allardyce TJ, et al. Placement of pedicle screws in the thoracic spine. Part I: morphometric analysis of the thoracic vertebrae. J Bone Joint Surg Am. 1995;77(8):1193e1199.

Samdani Amer F, Ranade Ashish, Sciubba Daniel M, et al. Accuracy of free-hand placement of thoracic pedicle screwsin adolescent idiopathic scoliosis: howmuch of a difference does surgeon experience make? Eur Spine J. 2010;19(1):91e95.

Amiot LP, Lang K, Putzier M, Zippel H, Labelle H. Comparative results between conventional and computer-assisted pedicle screw installation in the thoracic, lumbar, and sacral spine. Spine (Phila Pa 1976). 2000;25(5):606e614.

Kuklo TR, Lenke LG, O'Brien MF, Lehman Jr RA, Polly Jr DW, Schroeder TM. Accuracy and efficacy of thoracic pedicle screws in curves more than 90 degrees. Spine (Phila Pa 1976). 2005;30(2):222e226.

Fayyazi AH, Hugate RR, Pennypacker J, Gelb DE, Ludwig SC. Accuracy of computed tomography in assessing thoracic pedicle screw malposition. J Spinal Disord Tech. 2004;17(5):367e371.

O'Brien MF, Lenke LG, Mardjetko S, et al. Pedicle morphology in thoracic adolescent idiopathic scoliosis: is pedicle fixation an anatomically viable technique? Spine (Phila Pa 1976). 2000;25(18):2285e2293.

Misenhimer GR, Peek RD, Wiltse LL, Rothman SL, Widell Jr EH. Anatomic analysis of pedicle cortical and cancellous diameter as related to screw size. Spine (Phila Pa 1976). 1989;14(4):367e372.

Hicks JM, Singla A, Shen FH, Arlet V. Complications of pedicle screw fixation in scoliosis surgery: a systematic review. Spine (Phila Pa 1976). 2010;35(11): E465eE470.

Sarwahi V, Wendolowski SF, Gecelter RC, et al. Are we underestimating the significance of pedicle screw misplacement? Spine (Phila Pa 1976). 2016;41(9): E548eE555.

Castro WH, Halm H, Jerosch J, Malms J, Steinbeck J, Blasius S. Accuracy of pedicle screw placement in lumbar vertebrae. Spine (Phila Pa 1976). 1996;21(11):1320e1324.

Silbermann J, Riese F, Allam Y, Reichert T, Koeppert H, Gutberlet M. Computer tomography assessment of pedicle screw placement in lumbar and sacral spine: comparison between free-hand and O-arm based navigation techniques. Eur Spine J. 2011;20(6):875e881.

Gelalis ID, Paschos NK, Pakos EE, et al. Accuracy of pedicle screw placement: a systematic review of prospective in vivo studies comparing free hand, fluoroscopy guidance and navigation techniques. Eur Spine J. 2012;21(2):247e255.

Sarlak AY, Buluç Levent, Sarısoy Hasan Tahsin, Memis¸ oglu Kaya, Tosun Bilgehan. Placement of pedicle screws in thoracic idiopathic scoliosis: a magnetic resonance imaging analysis of screw placement relative to structures at risk. Eur Spine J. 2008;17(5):657e662.

Kuklo TR, Lehman Jr RA, Lenke LG. Structures at risk following anterior instrumented spinal fusion for thoracic adolescent idiopathic scoliosis. J Spinal Disord Tech. 2005;18(Suppl):S58eS64.

Jiang J, Mao S, Zhao Q, et al. Different proximal thoracic curve patterns have different relative positions of esophagus to spine in adolescent idiopathic scoliosis: a computed tomography study. Spine (Phila Pa 1976). 2012;37(3): 193e199.

Minor ME, Morrissey NJ, Peress R, et al. Endovascular treatment of an iatrogenic thoracic aortic injury after spinal instrumentation: case report. J Vasc Surg. 2004;39(4):893e896.

Sariyilmaz K, Ozkunt O, Sungur M, Dikici F, Domanic U. Esophageal perforation caused by a posterior pedicle screw: a case report. J Pediatr Orthop. 2017;37(2): 98e101.

Weinstein JN, Rydevik BL, Rauschning W. Anatomic and technical considerations of pedicle screw fixation. Clin Orthop Relat Res. 1992;284:34e46.

Hirano T, Hasegawa K, Takahashi HE, et al. Structural characteristics of the pedicle and its role in screw stability. Spine (Phila Pa 1976). 1997;22(21): 2504e2509 [Discussion 2510].

George DC, Krag MH, Johnson CC, Van Hal ME, Haugh LD, Grobler LJ. Hole preparation techniques for transpedicle screws. Effect on pull-out strength from human cadaveric vertebrae. Spine (Phila Pa 1976). 1991;16(2):181e184.

Saraf SK, Singh RP, Singh V, Varma A. Pullout strength of misplaced pedicle screws in the thoracic and lumbar vertebrae - A cadaveric study. Indian J Orthop. 2013;47(3):238e243.

Tan CE, Fok MW, Luk KD, Cheung KM. Insertional torque and pullout strength of pedicle screws with or without repositioning: a porcine study. J Orthop Surg (Hong Kong). 2014;22(2):224e227.

Wadhwa RK, Thakur JD, Khan IS, et al. Adjustment of suboptimally placed lumbar pedicle screws decreases pullout strength and alters biomechanics of the construct: a pilot cadaveric study. World Neurosurg. 2015;83(3):368e375.

Brasiliense LB, Theodore N, Lazaro BC, et al. Quantitative analysis of misplaced pedicle screws in the thoracic spine: how much pullout strength is lost?: presented at the 2009 joint spine section meeting. J Neurosurg Spine. 2010;12(5):503e508.
Acta Orthopaedica et Traumatologica Turcica-Cover
  • ISSN: 1017-995X
  • Başlangıç: 2015
  • Yayıncı: Türk Ortopedi ve Travmatoloji Derneği
Sayıdaki Diğer Makaleler

Psoas hematoma formation after violation of the intertransverse plane during posterior spinal surgery for adolescent idiopathic scoliosis

Marvin Man Ting CHUNG, Jason Pui Yin CHEUNG

Effect of platelet-rich fibrin on epidural fibrosis and comparison to ADCON® Gel and hyaluronic acid

Esra DEMİREL, Kadri YILDIZ, Kenan ÇADIRCI, Hayati AYGÜN, Eyüp ŞENOCAK, BETÜL GÜNDOĞDU

Comment on: “Single anterior portal: A better option for arthroscopic treatment of traumatic anterior shoulder instability?” ( Author's response: )

Hakan ÇİÇEK

Thickness of plantar fascia is not predictive of functional outcome in plantar fasciitis treatment

CENK ERMUTLU, Murat AKSAKAL, Ayşem GÜMÜŞTAŞ, GÜVEN ÖZKAYA, EMRAH KOVALAK, Yüksel ÖZKAN

Chondroblastoma: An evaluation of the recurrences and functional outcomes following treatment

Devrim ÖZER, Yavuz ARIKAN, Volkan GUR, Cantay GÖK, Yunus Emre AKMAN

Comment on: “Single anterior portal: A better option for arthroscopic treatment of traumatic anterior shoulder instability?”

Adrian TODOR

Rate of conversion of reports presented at the Turkish Society of Sports Traumatology, Arthroscopy and Knee Surgery Congress into publication

Murat GÜLCEK, Fatih İNCİ, Erman CEYHAN, Utku GÜRHAN, Yakup KAHVE, Ahmet UÇANER

T-plate fixation for unstable proximal clavicula fractures

Yi ZHENG, Xin-Hua YUAN, Yi-Hong YİN, Wei-Bin WANG, Qing-Song FU, Qing-Jiang PANG

Ultrasonographic comparison of bilateral patellar tendon dimensions in patients treated via intramedullary tibial nailing using a transpatellar approach

Samet ERİNÇ, Irfan ESENKAYAE, OĞUZ ŞÜKRÜ POYANLI, Burak ÖZTURAN, Muzaffer AYAZ, Afşar TİMUÇİN ÖZTÜRK

Quantitative comparison of a laterally misplaced pedicle screw with a re-directed screw. How much pull-out strength is lost?

Murat KORKMAZC, Kerim SARIYILMAZ, Okan OZKUNTA, HALİL CAN GEMALMAZ, TURGUT AKGÜL, Mustafa SUNGUR, FATİH DİKİCİ, MURAT BAYDOĞAN